Special Tools
| • | J 8001 Dial Indicator Set |
| • | J 26900-13 Magnetic Indicator Base |
| • | J 35138 Converter End Play Checker
|
For equivalent regional tools, refer to
Special Tools.
- Position the torque converter (1) on the bench with the flywheel lugs facing down.
- Install
J 26900-13 magnetic indicator base
,
J 35138 end play checker
, and
J 8001 dial indicator set
onto the torque converter (1).
- Set the dial indicator to 0.
- Lift
J 35138 end play checker
and note the dial indicator reading:
| • | The torque converter end play should be 0.5 mm (0.020 in) or less |
| • | If the end play is too high, replace the torque converter (1) |
- Inspect and replace the torque converter (1) for the following conditions:
| • | Overheated (torque converter will be blue in color) |
| • | Leaking at the weld areas |
| • | A damaged torque converter pilot |
| • | Evidence of metal particles in the converter, the oil cooler, or the cooler pipes |
| • | A damaged torque converter stator, a damaged pump, or a damaged turbine |
| • | A damaged or worn torque converter bushing (2) |
| • | Contaminated automatic transmission fluid due to engine coolant |
- Inspect the torque converter for stripped bolt hole threads. If found, repair the torque converter.