Special Tools
J-39400-A Halogen Leak Detector
Removal Procedure
- Recover the refrigerant from the air conditioning (A/C) system. Refer to
Refrigerant Recovery and Recharging .
Note: Immediately cap or tape the open A/C compressor opening immediately in order to prevent system contamination.
- Remove the high pressure relief valve (1).
- Remove and discard the O-ring seal (2).
- Cap or tape the pressure relief valve port .
Installation Procedure
- Lubricate and install the NEW O-ring seal (2). Refer to
O-Ring Replacement .
Caution: Refer to Fastener Caution in the Preface section.
- Remove the cap or tape from the pressure relief valve port .
- Install the high pressure relief valve (1) and tighten to
12 N·m (106 lb in)
.
- Evacuate and recharge the A/C system. Refer to
Refrigerant Recovery and Recharging .
- Leak test the fitting of the component using
J 39400-A .