Special Tools
J-39400-A Halogen Leak Detector
Removal Procedure
- Recover the refrigerant from the air conditioning (A/C) system. Refer to
Refrigerant Recovery and Recharging .
- Drain the cooling system. Refer to
Cooling System Draining and Filling .
Note: The defroster door must be closed to allow clearance during defroster duct removal.
- Set the heating, ventilation and air conditioning (HVAC) controls in the vent setting to close the defroster door.
- Remove the blower motor. Refer to
Blower Motor Replacement .
- Disconnect the electrical connector from the blower motor resistor.
- Disconnect the electrical connector from the evaporator temperature sensor.
- Disconnect all of the HVAC actuator electrical connectors.
- Remove the instrument panel (I/P) carrier. Refer to
Instrument Panel Carrier Replacement .
- Remove the evaporator outlet tube nut.
- Disconnect the evaporator outlet tube and evaporator inlet tube from the thermal expansion valve (TXV).
- Remove and discard the sealing washers.
- Remove the heater inlet and outlet hoses. Refer to
Heater Inlet Hose/Pipe and Heater Outlet Hose/Pipe Replacement .
- Remove the HVAC module nuts.
Installation Procedure
Note: Ensure proper alignment of the HVAC module and drain tube through the cowl.
- Install the HVAC module.
Caution: Refer to Fastener Caution in the Preface section.
- Install the HVAC module to the dash panel sound barrier nuts and tighten to
10 N·m (89 lb in)
.
- Install the heater inlet and outlet hoses. Refer to
Heater Inlet Hose/Pipe and Heater Outlet Hose/Pipe Replacement .
- Install NEW sealing washers.
- Connect the evaporator inlet and outlet tube block to the TXV.
- Install the evaporator tube block nut and tighten to
16 N·m (12 lb ft)
.
- Install the I/P carrier. Refer to
Instrument Panel Carrier Replacement .
- Connect all of the HVAC actuator electrical connectors.
- Connect the electrical connector to the evaporator temperature sensor.
- Connect the electrical connector to the blower motor resistor.
- Install the blower motor. Refer to
Blower Motor Replacement .
- Fill the cooling system. Refer to
Cooling System Draining and Filling .
- Evacuate and recharge the A/C system. Refer to
Refrigerant Recovery and Recharging .
- Leak test the fittings using the
J-39400-A detector
.