Step | Action | Yes | No |
---|---|---|---|
1 | Did you review the Automatic Level Control System Description and Operation and perform the necessary inspections? | Go to Step 2 | |
2 | Verify ALC system operation. Does the ALC system operate normally? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Did the ALC air compressor activate? | Go to Step 4 | Go to Step 5 |
4 |
Did the test lamp illuminate? | Go to Step 6 | Go to Step 7 |
5 | Repair the open in the ALC relay coil supply voltage circuit. Did you complete the repair? | Go to Step 12 | -- |
6 | Connect a test lamp between the battery positive circuit of the ALC sensor connector and a good ground. Did the test lamp illuminate? | Go to Step 8 | Go to Step 9 |
7 | Replace the ALC air inflator relay. Refer to Automatic Level Control Relay Replacement . Did you complete the repair? | Go to Step 12 | -- |
8 |
Did the test lamp illuminate? | Go to Step 10 | Go to Step 11 |
9 | Repair the open in the ground circuit of the ALC sensor connector. Did you complete the repair? | Go to Step 12 | -- |
10 | Replace the ALC sensor. Refer to Automatic Level Control Sensor Replacement . Did you complete the replacement? | Go to Step 12 | -- |
11 | Repair the open in the accessory voltage circuit. Did you complete the repair? | Go to Step 12 | -- |
12 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |