Step | Action | Value(s) | Yes | No | ||||
---|---|---|---|---|---|---|---|---|
DEFINITION: The roof rail reading lamps do not activate when the following conditions exist:
| ||||||||
1 | Did you perform the Lighting Systems Diagnostic System Check? | -- | Go to Step 2 | |||||
2 | Operate all of the roof rail reading lamps. Do all of the roof rail reading lamps work properly? | -- | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 3 | ||||
3 | Inspect the filament of the inoperative roof rail reading lamps bulb(s). Is there any bulb filament open? | -- | Go to Step 7 | Go to Step 4 | ||||
4 | Test for an open in the supply voltage circuit to the inoperative roof rail reading lamp. Did you find and correct the condition? | -- | Go to Step 8 | Go to Step 5 | ||||
5 | Test for an open in the ground(s) circuit to the inoperative roof rail reading lamp. Did you find and correct the condition? | -- | Go to Step 8 | Go to Step 6 | ||||
6 | Replace the inoperative roof rail reading lamp. Did you complete the repair? | -- | Go to Step 8 | -- | ||||
7 | Replace the inoperative roof rail reading lamp bulb(s). Did you complete the repair? | -- | Go to Step 8 | -- | ||||
8 |
Did you correct the condition? | -- | System OK | Go to Step 3 |