Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you review the operation and perform the necessary inspections? | -- | Go to Symptoms | |
2 | Is only one rear quarter window inoperative? | -- | ||
3 |
Does the test lamp illuminate after both actions? | -- | ||
4 |
Does the test lamp illuminate? | -- | ||
5 | Replace the inoperative quarter window actuator. Refer to Body Side Window Actuator Replacement . Is the repair complete? | -- | -- | |
6 |
Does the test lamp illuminate? | -- | ||
7 | Repair the poor connection or open in circuit 901 between S423 and the inoperative quarter window actuator terminal A. Refer to Wiring Repairs or Connector Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
8 | Repair the poor connection or open in circuit 902 between S427 and the inoperative quarter window actuator terminal B. Refer to Wiring Repairs or Connector Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
9 | Using a test lamp, probe the interior lamp and multi-function switch (rear quarter window switch) connector C4 from terminals E and B. Refer to Circuit Testing in Wiring Systems. Does the test lamp illuminate? | -- | ||
10 | Check PWR QTR VENT fuse. Is the fuse open? | -- | ||
11 |
Does the test amp illuminate in both cases? | -- | ||
12 | Repair the poor connection or open in circuit 650. Refer to Wiring Repairs or Connector Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
13 | Check for a short to ground in circuit 743. Refer to Circuit Testing in Wiring Systems. Is a short to ground present? | -- | ||
14 | Repair the poor connection or open in circuit 743 or the RAP relay circuit (if the power windows are also inoperative). Refer to Wiring Repairs or Connector Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
15 | Check for a poor connection or open in circuit 901. Refer to Circuit Testing in Wiring Systems. Is there an open present? | -- | ||
16 | Replace the interior lamp and multi-function switch. Refer to Quarter Window Switch Replacement . Is the repair complete? | -- | -- | |
17 | Repair the short to ground in circuit 743. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
18 | Check for a short to ground in circuit 901. Refer to Circuit Testing in Wiring Systems. Is a short to ground present? | -- | ||
19 | Repair the poor connection or open in circuit 901. Refer to Wiring Repairs or Connector Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
20 | Repair the poor connection or open in circuit 902. Refer to Wiring Repairs or Connector Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
21 | Repair the short to ground in circuit 901. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
22 | Check for a short to ground in circuit 902. Refer to Circuit Testing in Wiring Systems. Is a short to ground present? | -- | ||
23 | Repair the short to ground in circuit 902. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
24 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK |