Removal Procedure
- Remove the vacuum lines from the secondary
air injection (AIR) solenoid.
- Disconnect the electrical connector from the AIR solenoid.
- Remove the AIR solenoid to bracket screw.
- Remove the AIR solenoid from the bracket.
Installation Procedure
- Install the AIR solenoid to the bracket.
Notice: Refer to Fastener Notice in the Preface section.
- Install the AIR solenoid to bracket screw.
Tighten
Tighten the fasteners to 10 N·m (89 lb in).
- Install the electrical connector to the AIR solenoid.
- Install the vacuum lines to the AIR solenoid.