Important: Count the number of threads showing from the tip of the mode actuator push rod to the end of the retainer clip.
Important: Disconnect the IP wiring harness clip from the IP support bracket to help access the mode actuator screws.
Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
Tighten
Tighten the screws to 1.6 N·m (14 lb in).
Important: Align the counted number of threads on the mode actuator push rod (2) with the tip of the retainer clip (1).