The number below refers to the step number on the diagnostic table.
Step | Action | Value(s) | Yes | No | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The temperature cannot be adjusted, or the heating is insufficient. | ||||||||||||||||
1 |
Important: Both left (driver) and right (passenger) air temperature control concerns are diagnosed in this table. Did you perform the HVAC Diagnostic System Check? | -- | Go to Step 2 | |||||||||||||
2 |
Does the blower motor operate in any speed position? | -- | Go to Step 3 | Go to Blower Motor Inoperative | ||||||||||||
3 | Does the blower motor operate in each speed position? | -- | Go to Step 4 | Go to Blower Motor Malfunction | ||||||||||||
4 |
Does the recirculation door move to the correct position? | -- | Go to Step 5 | |||||||||||||
5 | Except for the blower motor speed, are all of the functions of the HVAC control module inoperative? | -- | Go to Step 14 | Go to Step 6 | ||||||||||||
6 | Inspect the cooling system for the following conditions:
Did you find and correct the condition? | -- | Go to Step 23 | Go to Step 7 | ||||||||||||
7 |
Does the A/C compressor operate? | -- | Go to Step 8 | |||||||||||||
8 |
Does the left and right air temperature actuator drive shaft rotate? | -- | Go to Step 9 | Go to Step 10 | ||||||||||||
9 | Inspect the left and right air temperature door and the left and right air temperature actuator for the following conditions:
Did you find and correct the condition? | -- | Go to Step 23 | Go to Heating Performance Diagnostic in Heating, Ventilation and Air Conditioning | ||||||||||||
10 | Test the ignition 3 voltage circuit of the suspect air temperature actuator for an open or a high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 23 | Go to Step 11 | ||||||||||||
11 | Test the ground circuit of the suspect air temperature actuator for an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 23 | Go to Step 12 | ||||||||||||
12 | Test the air temperature door control circuit of the suspect air temperature actuator for an open, high resistance, short to ground, or short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 23 | Go to Step 13 | ||||||||||||
Important: Ensure that the HVAC control module connector is connected during this step in order to avoid misdiagnosis.
Does the voltage measure within the specified values with a smooth transition between cold and hot? | 0.25 V at cold 14.7 V at hot | Go to Step 18 | Go to Step 20 | |||||||||||||
14 | Test the ignition 3 voltage circuit of the HVAC control module for an open or a high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 23 | Go to Step 15 | ||||||||||||
15 | Test the battery positive voltage circuit of the HVAC control module for an open or a high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 23 | Go to Step 16 | ||||||||||||
16 | Test the OFF blower motor control circuit of the HVAC control module for a short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 23 | Go to Step 17 | ||||||||||||
17 | Test the ground circuit of the HVAC control module for an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 23 | Go to Step 20 | ||||||||||||
18 | Inspect for poor connections at the harness connector of the suspect air temperature actuator. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 23 | Go to Step 19 | ||||||||||||
19 | Inspect the suspect air temperature actuator, door and any attaching linkage for binding or a condition that prevents drive shaft rotation.
Did you find and correct the condition? | -- | Go to Step 23 | Go to Step 21 | ||||||||||||
20 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 23 | Go to Step 22 | ||||||||||||
21 | Replace the suspect air temperature actuator. Refer to Air Temperature Actuator Replacement - Right Side or Air Temperature Actuator Replacement - Left Side . Did you complete the replacement? | -- | Go to Step 23 | -- | ||||||||||||
22 | Replace the HVAC control module. Refer to HVAC Control Module Replacement . Did you complete the replacement? | -- | Go to Step 23 | -- | ||||||||||||
23 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 2 |