GM Service Manual Online
For 1990-2009 cars only

Removal Procedure

    Caution: Refer to SIR Inflator Module Handling and Storage Caution in the Preface section.

  1. Disable the SIR system. Refer to SIR Disabling and Enabling .
  2. Remove the instrument panel (I/P) compartment and the electrical connector from the I/P compartment lamp. Refer to Instrument Panel Compartment Replacement in Instrument Panel, Gages and Console.
  3. Remove the I/P module pigtail harness clips from the I/P carrier bracket.

  4. Object Number: 260611  Size: MH
  5. Remove the mounting fasteners (4) that attach the inflatable restraint module to the I/P.
  6. Remove the bolts (5) that attach the inflatable restraint I/P module to the cross-car beam.
  7. Remove the inflatable restraint I/P module (1) from the vehicle.
  8. Fully deploy the module before disposal. If the module was replaced under warranty, fully deploy and dispose of the module after the required retention period. Refer to Inflator Module Handling and Scrapping .

Installation Procedure


    Object Number: 260611  Size: MH
  1. Install the inflatable restraint I/P module (1) to the vehicle.
  2. Install the inflatable restraint I/P module bolts (5).
  3. Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.

  4. Install the inflatable restraint I/P module mounting fasteners (4).
  5. Tighten
    Tighten fasteners to 10 N·m (89 lb in).

  6. Install the pigtail harness clips on the module to the I/P carrier bracket.
  7. Install the electrical connector to the I/P compartment lamp and install the I/P compartment. Refer to Instrument Panel Compartment Replacement in Instrument Panel, Gages and Console.
  8. Enable the SIR system. Refer to SIR Disabling and Enabling .