Tools Required
J 25070 Heat Gun
Removal Procedure
- Remove the molding. Refer to
Door Body Side Molding Replacement
.
Caution: Wear safety glasses in order to avoid eye damage.
- To release the molding push-in retainers, perform the
following steps:
2.1. | Drill a 3 mm (0.125 in) hole into the center locking
pin of the push-in retainer. |
2.2. | Install a 3.175 mm (0.125 in) screw into the center
locking pin of the push-in retainer. |
2.3. | Use a pair of pliers to pull out the screw and unlock the push-in
retainer. |
- Using J 25070
,
heat the upper edge of the retainer using a circular motion 152 mm
(6 in) from the retainer for 30 seconds.
Notice: Use a plastic, flat-bladed tool to prevent paint damage when removing
an emblem/name plate.
- Use a plastic flat-bladed tool to remove the retainer from the outer
door panel.
Installation Procedure
- Use isopropyl alcohol to clean the area of the panel where the
retainer will be installed.
- Use a J 25070
to heat the outer door panel surface to 27-41°C (80-105°F),
if necessary.
- Ensure that the retainer is approximately room temperature 22°C
(72°F).
Important: Do NOT touch the adhesive backing on the retainer.
- Remove the protective liner from the back of the retainer.
- Align the push-in retainers to the holes in the outer door panel.
- Press the molding to the outer door panel until fully seated.
- Press on the retainer center locking pins until fully seated.
- Install the molding to the side door. Refer to
Door Body Side Molding Replacement
.