The efficient operation and life of the air conditioning (A/C) system is dependent upon the chemical stability of the refrigeration system. When foreign materials, such as dirt, air, or moisture, contaminate the refrigeration system, they will change the stability of the refrigerant and the polyalkalene glycol (PAG) compressor oil. They will also affect the pressure-temperature relationship, reduce efficient operation, and can possibly cause interior corrosion and abnormal wear of moving parts.
Observe the following practices to ensure chemical stability in the system:
• | Wipe away dirt or oil at and near any connection before opening that connection. This will reduce the chance of dirt entering the system. |
• | Cap, plug, or tape both sides of a connection as soon as possible after opening the connection. This will prevent the entry of dirt, foreign material, and moisture. |
• | Keep all tools clean and dry, including the manifold gage set and all replacement parts. |
• | Use a clean and dry transfer device and container to add PAG refrigerant oil. This will ensure that the oil remains as moisture-free as possible. Refer to Discharging, Adding Oil, Evacuating, and Charging Procedures for the A/C System for the instructions to perform this procedure properly. |
All service parts are dehydrated and sealed before shipping. They should remain sealed until just before making connections. All the parts should be at room temperature before uncapping. This prevents condensation of moisture from the air from entering the system. Reseal all parts as soon as possible if the caps have been removed but the connections cannot be made promptly.
Caution: Avoid breathing the A/C Refrigerant 134a (R-134a) and the lubricant vapor or the mist. Exposure may irritate the eyes, nose, and throat. Work in a well ventilated area. In order to remove R-134a from the A/C system, use service equipment that is certified to meet the requirements of SAE J 2210 (R-134a recycling equipment). If an accidental system discharge occurs, ventilate the work area before continuing service. Additional health and safety information may be obtained from the refrigerant and lubricant manufacturers.
Caution: Refer to Protective Goggles and Glove Caution in the Preface section.
A charging station discharges, evacuates, and recharges an A/C system with one hookup.
Filtering the refrigerant during the recovery cycle together with filtering during the evacuation cycle ensures a supply of clean, dry refrigerant for A/C system charging.
Notice: R-12 refrigerant and R-134a refrigerant must never be mixed, even in the smallest of amounts, as they are incompatible with each other. If the refrigerants are mixed, compressor failure is likely to occur. Refer to the manufacturer instructions included with the service equipment before servicing.
There are many charging stations available. All perform the various tasks required to discharge the system and recover refrigerant, evacuate the system, add a measured amount of oil, and recharge an air conditioning system with a measured amount of refrigerant. Refer to the manufacturer's instructions for all initial setup procedures and all maintenance procedures.
A charging station will have controls and indicators to allow the operator to control and monitor the operation in progress. Refer to the manufacturer's instructions for details. These can be expected to include the following:
• | Shows the time programmed for vacuum |
• | Shows the weight of the refrigerant programmed for recharging |
• | Refer to the manufacturer's instructions for detailed programming information. |
Important: Use only a refrigerant tank that is designed for the charging station in use. The unit's overfill limitation mechanism is calibrated specifically for use with this tank. The tank valves are also manufactured specifically for this unit.
Important: If there is no refrigerant in the system, do not continue with the recovery operation. Under this condition, this would draw air into the recovery tank.
Notice: Do not mix the old PAG oil with new PAG oil. The old oil may have aluminum deposits or other foreign material mixed in the oil. Always use new refrigerant PAG oil when refilling the A/C system. Dispose of the used refrigerant oil properly.
Important: Some A/C system PAG lubricating oil may be removed with the refrigerant during recovery. The amount of oil removed varies. A charging station separates the oil from the refrigerant and provides a means of determining how much oil was removed. Replace the same amount of oil when recharging the system.
Refer to the manufacturer's instructions for the charging station in use.Important: If the control indicator shows that the refrigerant tank is full during the recovery process and the unit shuts off, install an empty unit tank to store the refrigerant needed for steps later in the procedure. Do not use any other type of tank.
The unit tank must contain a sufficient amount of R-134a refrigerant for charging. Measure the amount of refrigerant in the tank. If there is less than 3.6 kg (8 lb) of refrigerant, add new refrigerant to the tank. Refer to the manufacturer's instructions for adding refrigerant.
Important: Refer to the manufacturer's instructions for the charging station in use. It is necessary to evacuate the system before recharging it with new or recycled refrigerant.
Important: Change the vacuum pump oil frequently. Refer to the manufacturer's instructions for the charging station in use.
Any oil removed from the A/C system during the recovery process must be replenished at this time.
Important: Refer to the manufacturer's instructions for the charging station in use. Add the proper amount of PAG oil to the system.
Important: Evacuate the A/C system before charging.
Sometimes the total charge does not transfer into the A/C system. There are 2 reasons why this may occur:
• | This will cause the transfer to proceed too slowly. |
• | Refer to the manufacturer's instructions for the charging station in use. |
• | It is necessary to recover the partial charge of refrigerant from the vehicle and then evacuate and charge the A/C system again. |
• | Refer to the manufacturer's instructions for the charging station in use. |