Step | Action | Values | Yes | No |
---|---|---|---|---|
1 |
Does the battery voltage available at the backup lamp socket positive terminal within the specified value? | 11-14 V | Go to Step 3 | Go to Step 2 |
2 | Repair the open circuit between fuse F15 and the backup lamps. Is the repair complete? | -- | System OK | -- |
3 | Connect an ohmmeter between ground and the negative terminal at the bulb socket. Is the resistance equal to the specified value? | 0 ohms | Go to Step 4 | Go to Step 5 |
4 | Replace the faulty backup lamps. Is the repair complete? | -- | System OK | -- |
5 |
Is the voltage available at terminal 1 within the specified value? | 11-14 V | Go to Step 7 | Go to Step 6 |
6 | Repair the open circuit between the backup lamps and the reverse switch. Is the repair complete? | -- | System OK | -- |
7 |
Does the continuity between terminals 1 and 2, terminals 7 and 8 with A/T, equal the specified value? | 0 ohms | Go to Step 9 | Go to Step 8 |
8 | Replace the REVERSE switch. Is the repair complete? | -- | System OK | -- |
9 | Repair the ground circuit between REVERSE switch and the backup lamps. Is the repair complete? | -- | System OK | -- |