Removal Procedure
Caution: Refer to Battery Disconnect Caution in the Preface section.
- Disconnect the negative battery cable.
- Recover the refrigerant. Refer to
Refrigerant Recovery and Recharging
.
- Remove 2 bolts and the air inlet duct.
- Remove the nut on the flange of the compressor and sealing washer.
- Remove the nut on the flange of the condenser.
- Remove the O-ring and discard it.
- Remove the discharge hose.
Installation Procedure
- Install the discharge hose.
- Install a new O-ring seal to the discharge hose at the condenser flange.
Notice: Refer to Fastener Notice in the Preface section.
- Install the nut to the condenser flange.
Tighten
Tighten the nut to 16 N·m (12 lb ft).
Important: The washers must be seated to the surface of the block fitting.
- Install new sealing washers to the pilots of the suction/discharge block fitting.
- Install the nut on the compressor flange.
Tighten
Tighten the nut to 33 N·m (24 lb ft).
- Install the 2 bolts and the air inlet duct.
Tighten
Tighten the bolts to 8 N·m (71 lb in).
- Evacuate and recharge the A/C system. Refer to
Refrigerant Recovery and Recharging
.
- Connect the negative battery cable.