Step | Action | Values | Yes | No |
---|---|---|---|---|
1 | Check the fuse F18. Is the fuse open? | -- | Go to Step 2 | Go to Step 3 |
2 | Repair any short circuit and replace the open fuses. Did you complete the repair? | -- | System OK | -- |
3 |
Does the voltage measure within the specified value? | 11-14 V | Go to Step 4 | Go to Step 5 |
4 |
Did you complete the repair? | -- | System OK | -- |
5 | Measure the resistance between terminal A16 of the connector and ground. Does the resistance measure equal to the specified value? | 0 ohms | Go to Step 6 | Go to Step 7 |
6 | Repair the open circuit between fuse F18 and terminal A7. Did you complete the repair? | -- | System OK | -- |
7 | Repair the open circuit between terminal A16 and ground. Did you complete the repair? | -- | System OK | -- |