Step | Action | Values | Yes | No |
---|---|---|---|---|
1 | Inspect fuse F16. Is fuse F16 blown? | -- | Go to Step 2 | Go to Step 3 |
2 |
Is the repair complete? | -- | System OK | -- |
3 | Use a voltmeter to measure the voltage at fuse F16. Is the voltage within the value specified? | 11-14 V | Go to Step 5 | Go to Step 4 |
4 | Repair the open circuit between the battery and fuse F16. Is the repair complete? | -- | System OK | -- |
5 |
Is the voltage within the value specified? | 11-14 V | Go to Step 7 | Go to Step 6 |
6 | Repair the open circuit between fuse F16 and the glove box lamp terminal 2. Is the repair complete? | -- | System OK | -- |
7 | Use an ohmmeter to measure continuity between terminal 1 of the glove box lamp connector and ground. Is the ohmmeter show the specified value? | 0 ohms | Go to Step 8 | Go to Step 9 |
8 | Replace the glove box lamp bulb. Is the repair complete? | -- | System OK | -- |
9 | Repair the ground circuit for the glove box lamp. Is the repair complete? | -- | System OK | -- |