Removal Procedure
Caution: Refer to Battery Disconnect Caution in the Preface section.
- Disconnect the negative battery cable.
- Recover the refrigerant. Refer to
Refrigerant Recovery and Recharging
.
- Remove the air cleaner hose clamp.
- Remove the 3 bolts that secure the air cleaner housing and remove the air cleaner housing.
- Disconnect the pressure sensor connector.
- Remove the pressure sensor connector.
Installation Procedure
- Install a new O-ring seal on the pressure sensor.
- Install the pressure sensor.
Notice: Refer to Fastener Notice in the Preface section.
- Connect the pressure sensor connector.
Tighten
Tighten the pressure sensor to 7 N·m (62 lb in).
- Install the air cleaner housing and bolts.
- Install the air cleaner hose clamp.
- Evacuate and recharge the A/C system. Refer to
Refrigerant Recovery and Recharging
.
- Connect the negative battery cable.