This code will set if the output of the mix door indicator indicates that the door opening angle is out of range or does not change value when the door should be moving. This would indicate a short circuit or an open in the sensor or the associated wiring harness, a door motor that is not operating, or a malfunction of the automatic temperature control (ATC) controller.
Step | Action | Value(s) | Yes | No | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 |
Does the measured resistance indicate an open or a shorted condition? | -- | Go to Step 4 | Go to Step 2 | ||||||||||
2 | Measure the resistance between terminals 2 and 3 on the AMD motor. Is the resistance measured equal to the specified value? | 3000 ohms | Go to Step 3 | Go to Step 4 | ||||||||||
3 | Measure the resistance between terminals 6 and 2 and between terminals 6 and 3 on the AMD motor. Do these resistances add up to approximately the value measured between terminals 2 and 3? | 3000 ohms | Go yo Step 5 | Go to Step 4 | ||||||||||
4 | Replace the AMD motor. Did you complete the replacement? | -- | System OK | -- | ||||||||||
5 | Inspect the connector terminals at the AMD motor and the wiring in the ATC harness. Is there a problem with any terminal on either the harness connector or the motor connector or the wiring? | -- | Go to Step 6 | Go to Step 7 | ||||||||||
6 | Repair the problem found with a connector terminal or the wiring, or replace the motor as required. Did you find and correct the condition? | -- | System OK | -- | ||||||||||
7 |
Is there a problem with any of these connectors or the wiring? | -- | Go to Step 8 | Go to Step 9 | ||||||||||
8 | Repair the problem found with a connector terminal or wiring. Did you complete the repair? | -- | System OK | -- | ||||||||||
9 | Measure continuity in the harness between the controller connectors and the following AMD motor connectors:
Does the continuity equal the specified value? | 0 ohms | Go to Step 10 | Go to Step 11 | ||||||||||
10 | Repair the continuity problem. Did you complete the repair? | -- | System OK | -- | ||||||||||
11 |
Is the voltage measured less than or equal to the specified value? | 4 V | Go to Step 12 | Go to Step 14 | ||||||||||
12 |
Does the voltage equal the specified value? | 12 V to 0 V | Go to Step 13 | Go to Step 15 | ||||||||||
13 |
Does the voltage equal the specified value? | 12 V to 0 V | Go to Step 20 | Go to Step 15 | ||||||||||
14 |
Did you complete the repair? | -- | System OK | -- | ||||||||||
15 | Inspect all wiring circuits between the controller and the AMD motor. Is there a problem in the wiring or the connectors? | -- | Go to Step 16 | Go to Step 17 | ||||||||||
16 | Repair the condition in the wiring between the ATC controller and the AMD motor. Did you complete the repair? | -- | System OK | -- | ||||||||||
17 | Inspect the AMD motor. Is there a problem in the AMD motor? | -- | Go to Step 18 | Go to Step 19 | ||||||||||
18 | Replace the AMD motor. Did you complete the replacement? | -- | System OK | -- | ||||||||||
19 | Replace the controller. Did you complete the replacement? | -- | System OK | -- | ||||||||||
20 | Observe the operation of the air mix door when the temperature setting is changed. Does the door move normally? | -- | Go to Step 22 | Go to Step 21 | ||||||||||
21 | Repair or replace the air mix door. Did you find and correct the condition? | -- | System OK | -- | ||||||||||
22 | Observe the operation of the AMD motor when the temperature setting is changed. Does the motor operate normally? | -- | Go to Step 24 | Go to Step 23 | ||||||||||
23 | Replace the AMD motor. Did you complete the replacement? | -- | System OK | -- | ||||||||||
24 | Connect everything and test the system. Does DTC 4 reset? | -- | Go to Step 25 | System OK | ||||||||||
25 | Replace the controller. Did you complete the replacement? | -- | System OK | -- |