Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Backup Lamp Relay B+ | 1 | 1 | -- | -- |
Backup Lamp Relay Control | 1 | 1 | 1 | -- |
Backup Lamp Control | 1 | 1 | 1 | -- |
Backup Lamp Ground | -- | 1 | -- | -- |
1. Backup Lamps Malfunction |
The underhood fuse block supplies battery positive voltage to the coil and switch terminals of the backup lamps relay. When the transmission is placed in the REVERSE position, the transmission control module (TCM) sends a serial data message to the body control module (BCM). The message indicates that the gear selector is in the REVERSE position. The BCM grounds the backup lamp relay control circuit which energizes the backup lamps relay. With the relay energized, the switch side contacts close and provide battery voltage to the backup lamps fuse through to the backup lamps. The backup lamps are permanently grounded at G402. With both power and ground the backup lamps illuminate. Once the driver moves the gear selector out of the REVERSE position, a message is sent by the TCM via serial data requesting the BCM to remove ground from the backup lamp relay control circuit. This opens the backup lamps relay switch contacts turning OFF the backup lamps.
Exterior Lighting Systems Description and Operation
Control Module References for scan tool information
⇒ | If the test lamp illuminates, test the control circuit for a short to voltage. |
⇒ | If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. If the circuit tests normal and the B+ fuse is open, test the control circuit terminal 87 for a short to ground. If the circuit tests normal, test or replace the backup lamp relay. |
⇒ | If the test lamp does not illuminate, test the B+ circuit for an open/high resistance. |
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If the backup lamps do not illuminate, test the control circuit for an open/high resistance. If the circuit tests normal, replace the inoperative backup lamp. |
⇒ | If the test lamp is always ON, test the control circuit for a short to ground. If the circuit tests normal, replace the BCM. |
⇒ | If the test lamp is always OFF, test the control circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the BCM. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.