Subject:Blower Motor Is Inoperative

Models:2008 Buick Enclave
2007-2008 GMC Acadia
2007-2008 Saturn Outlook



The following diagnosis might be helpful if the vehicle exhibits the symptom(s) described in this PI.

Condition/Concern:

On rare occasions the customer may comment that the blower motor is inoperative and may have signs of water intrusion on the motor like rust or corrosion. If rust or corrosion is found on the blower motor, Check for a water leak from the cowl area.

Recommendation/Instructions:

Follow the instructions below to check for missing seam sealer in the cowl area.


Object Number: 2048841  Size: SH
  1. Remove the Air Inlet Grille Panel (see picture above). Follow SI instructions for Air Inlet Grille Panel Replacement.

  2. Object Number: 2048842  Size: SH

    Object Number: 2048843  Size: SH
  3. On the passenger side of the vehicle put a hose on the seams shown in the above pictures. Be careful not to let water run over the opening for HVAC fresh air intake.
  4. If a leak is found at one of the body seams, use a seam sealer to repair the leak.

Please follow this diagnostic or repair process thoroughly and complete each step. If the condition exhibited is resolved without completing every step, the remaining steps do not need to be performed.