The control module enables the fuel pump relay when the ignition switch is turned ON. The control module will disable the fuel pump relay within 2 seconds unless the control module detects ignition reference pulses. The control module continues to enable the fuel pump relay as long as ignition reference pulses are detected. The control module disables the fuel pump relay within 2 seconds if ignition reference pulses cease to be detected and the ignition remains ON.
The fuel tank stores the fuel supply. The electric fuel pump supplies fuel through an in-line fuel filter to the fuel injection system. The pump provides fuel at a higher rate of flow than is needed by the fuel injection system. The fuel pressure regulator maintains the correct fuel pressure to the fuel injection system. A separate pipe returns unused fuel to the fuel tank.
Step | Action | Values | Yes | No | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Did you perform the Diagnostic System Check - Vehicle? | -- | Go to Step 2 | Go to Diagnostic System Check - Vehicle in Vehicle DTC Information | ||||||||
2 |
Important: Inspect the fuel system for damage or external leaks before proceeding with this diagnostic.
Does the fuel pump operate? | -- | Go to Step 3 | |||||||||
3 |
Important: Verify that adequate fuel is in the fuel tank before proceeding with this diagnostic.
Important:
Is the fuel pressure within the specified range? | 345-395 kPa (50-57 psi) | Go to Step 4 | Go to Step 10 | ||||||||
4 |
Important: The fuel pressure may vary slightly when the fuel pump stops operating. After the fuel pump stops operating, the fuel pressure should stabilize and remain constant. Monitor the fuel pressure gage for 1 minute. Does the fuel pressure decrease by more than the specified value? | 34 kPa (5 psi) | Go to Step 7 | Go to Step 5 | ||||||||
5 |
Does the fuel pressure decrease by more than the second specified value? | 69 kPa (10 psi) 14 kPa (2 psi) | Go to Step 20 | Go to Step 6 | ||||||||
6 |
Do any of the scan tool parameters indicate a lean condition? | -- | Go to Step 14 | |||||||||
7 |
Is the fuel pressure regulator leaking fuel? | -- | Go to Step 19 | Go to Step 8 | ||||||||
8 |
Does the fuel pressure remain constant? | -- | Go to Step 16 | Go to Step 9 | ||||||||
9 |
Does the fuel pressure remain constant? | -- | Go to Step 19 | Go to Step 17 | ||||||||
10 | Is the fuel pressure more than the specified value? | 395 kPa (57 psi) | Go to Step 11 | Go to Step 13 | ||||||||
11 |
Is the fuel pressure within the specified range? | 345-395 kPa (50-57 psi) | Go to Step 18 | Go to Step 12 | ||||||||
12 | Inspect the fuel rail outlet passage and the fuel rail return pipe for a restriction. Did you find and correct the condition? | -- | Go to Step 21 | Go to Step 19 | ||||||||
13 |
Notice: DO NOT allow the fuel pressure to exceed 517 kPa (75 psi). Excessive pressure may damage the fuel system. Does the fuel pressure increase to more than the specified value? | 395 kPa (57 psi) | Go to Step 19 | Go to Step 14 | ||||||||
14 | Inspect the following components for a restriction:
Did you find and correct the condition? | -- | Go to Step 21 | Go to Step 15 | ||||||||
15 | Inspect the harness connectors and the ground circuits of the fuel pump for poor connections. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 21 | Go to Step 16 | ||||||||
16 |
Did you find and correct the condition? | -- | Go to Step 21 | Go to Step 20 | ||||||||
17 |
Did you complete the replacement. | -- | Go to Step 21 | |||||||||
18 | Repair the restricted fuel return pipe. Did you complete the repair? | -- | Go to Step 21 | -- | ||||||||
19 |
Important: Inspect for a missing or damaged O-ring seal before replacing the fuel pressure regulator. Replace the fuel pressure regulator. Refer to Fuel Pressure Regulator Replacement . Did you complete the replacement? | -- | Go to Step 21 | -- | ||||||||
20 | Replace the fuel tank module. Refer to Fuel Tank Module Replacement . Did you complete the replacement? | -- | Go to Step 21 | -- | ||||||||
21 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |