Step | Action | Yes | No | ||||
---|---|---|---|---|---|---|---|
Schematic Reference: Power Moding Schematics Connector End View Reference: Master Electrical Component List | |||||||
1 | Did you perform the Diagnostic System Check - Vehicle? | Go to Step 2 | |||||
2 | Do only the power windows and wipers exhibit this symptom? | Go to Step 5 | Go to Step 3 | ||||
3 |
Does the scan tool display change from Ajar to Door Closed respectively? | Go to Step 4 | |||||
4 |
Did the scan tool display the RAP power mode, then time-out and display Off-Awake power mode? | Go to Step 5 | Go to Step 9 | ||||
5 |
Do the power windows and wipers operate? | Go to Step 6 | Go to Step 7 | ||||
6 | Repair the short to battery in the power windows and wipers supply voltage circuit. Refer to Wiring Repairs . Did you complete the repair? | Go to Step 11 | -- | ||||
7 | Inspect for poor connections at the RAP relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 11 | Go to Step 8 | ||||
8 | Replace the RAP relay. Did you complete the replacement? | Go to Step 11 | -- | ||||
9 | Inspect for poor connections at the harness connector of the BCM. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 11 | Go to Step 10 | ||||
10 | Replace the BCM. Refer to Control Module References for replacement, setup, and programming. Did you complete the procedure? | Go to Step 11 | -- | ||||
11 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 1 |