Power window regulator (A31) shown, manual window regulator (without A31) similar.
Removal Procedure
- Remove the front door trim panel. Refer to
Front Side Door Trim Panel Replacement .
- Remove the front door water deflector. Refer to
Front Side Door Water Deflector Replacement .
- Remove the bolts retaining the front door window to the window regulator.
- Remove the front door window. Refer to
Front Side Door Window Replacement .
- Disconnect the electrical connector from the window regulator motor, if equipped with A31.
- Loosen the bolts (1) retaining the window regulator to the inner panel at the keyhole slot locations.
- Remove the remaining fasteners retaining the window regulator to the inner panel.
- Remove the window regulator from the door by lifting the regulator up, and out of the keyhole slots, and removing the regulator out through the access hole.
Installation Procedure
- Install the front door window regulator into the front door through the access hole.
- Position the window regulator to the inner panel by sliding the regulator bolts (1) into the keyhole slots in the inner panel.
Notice: Refer to Fastener Notice in the Preface section.
- Install the fastener retaining the front door window regulator to the door.
Tighten
Tighten the front window regulator fasteners to 9 N·m (80 lb in).
- Connect the electrical connector to the window regulator motor, if equipped with A31.
- Install the front door window. Refer to
Front Side Door Window Replacement .
- Install the bolts retaining the window to the window regulator.
Tighten
Tighten the front door window bolts to 9 N·m (80 lb in).
- Install the front door water deflector. Refer to
Front Side Door Water Deflector Replacement .
- Install the front door trim panel. Refer to
Front Side Door Trim Panel Replacement .