Removal Procedure
- Remove the air cleaner outlet duct. Refer to 
Air Cleaner Outlet Duct Replacement
.
 
- Disconnect the engine wiring harness electrical connector (1) from the mass airflow (MAF)/intake air temperature (IAT) sensor (2).
 
- Disconnect the secondary air injection (AIR) pump inlet hose (1) quick connect fitting from the air cleaner assembly. Refer to 
Plastic Collar Quick Connect Fitting Service
.
 
- Disengage the 2 air cleaner housing retainers (1).
 
- Open the air cleaner housing cover, and remove the air filter element (1).
 
Installation Procedure
- Install the air filter element (1), and close the air cleaner housing cover.
 
- Engage the 2 air cleaner housing retainers (1) securing the cover.
 
- Connect the AIR pump inlet hose (1) quick connect fitting to the air cleaner assembly. Refer to 
Plastic Collar Quick Connect Fitting Service
.
 
- Connect the engine wiring harness electrical connector (1) to the MAF/IAT sensor (2).
 
- Install the air cleaner outlet duct. Refer to 
Air Cleaner Outlet Duct Replacement
.