Diagnostic Instructions
DTC Descriptors
DTC B1390: Device Voltage Reference Input 1 Circuit - GBCM
Circuit/System Description
The generator battery control module (GBCM) monitors the battery voltage for precision electrical power management. The generator battery control module monitors both the battery sense positive voltage circuit and the battery sense negative, ground,
circuit to precisely determine system voltage. If there is a difference between the less precise battery voltage, battery positive voltage circuit and ground circuit, and the more precise battery sense voltage of 1.5 volts for 7 seconds, then DTC B1390
will set.
Conditions for Running the DTC
The ignition is ON.
Conditions for Setting the DTC
The difference between the low precision battery voltage reading and the high precision battery voltage reading is greater than 1.5 volts for 7 seconds.
Action Taken When the DTC Sets
• | The driver information center (DIC) displays the SERVICE CHARGE SYS message. |
• | The GBCM uses the less accurate battery positive voltage circuit for voltage readings. |
Conditions for Clearing the DTC
• | During the current ignition cycle, the difference between the less precision battery positive voltage circuit reading and the high precision battery voltage sense circuit reading is less than 1.5 volts. |
• | The SERVICE CHARGE SYS message will turn off 7 seconds after the voltage returns to normal. |
Diagnostic Aids
• | A possible cause of this DTC could be overcharging with a battery charger or jump starting. |
• | A high voltage value in multiple modules indicates a concern in the charging system. |
Reference Information
Schematic Reference
Control Module References
Connector End View Reference
Component Connector End Views
Description and Operation
Charging System Description and Operation
Electrical Information Reference
Scan Tool Reference
Control Module References
for scan tool information
Circuit/System Verification
- Engine running, accessories OFF, measure and record the battery voltage at the battery terminals. The voltage should be between 12.6 and 15.0 volts.
- Observe the scan tool BCM Battery Voltage Signal parameter and the Batt. Voltage High Res. parameter. The readings for both parameters should be between 12.6 and 15.0 volts, and should be within 1.5 volts of each other.
Circuit/System Testing
- Ignition OFF, disconnect the harness connectors at the GBCM.
- Ignition OFF and scan tool disconnected, open and close the driver door, and wait 1 minute. Test for less than 5 ohms between the ground circuit terminals listed below and ground:
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
- Verify that a test lamp illuminates between the B+ circuit terminals listed below and ground:
⇒ | If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. |
- If all circuits test normal, replace the GBCM.
Repair Instructions
Perform the
Diagnostic Repair Verification
after completing the diagnostic procedure.
Control Module References
for GBCM replacement, setup and programming.