• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open or High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
5-Volt Reference | P0641 | P0641, P06A6 | P0641 | P06A6 |
Fuel Rail Pressure (FRP) Sensor Signal | P0192 | P0191, P0192 | P0193 | P0191 |
Fuel Line Pressure Sensor Low Reference | -- | P0641, P06A6 | -- | P06A6 |
The fuel pressure sensor is located on the fuel line. The fuel pressure sensor monitors the fuel pressure in the fuel line. The fuel pump flow control module (FPCM) monitors the voltage signal from the fuel pressure sensor.
The ignition is on.
The FPCM detects that the fuel rail pressure (FRP) sensor signal circuit is above 4.9V or below 0.1V.
DTCs P0192 and P0193 are Type A DTCs.
DTCs P0192 and P0193 are Type A DTCs.
Using the Failure Records data may help locate an intermittent condition. If you cannot duplicate the DTC, the information in the Failure Records can help determine how many miles since the DTC set. The Fail Counter and Pass Counter can help determine how many ignition cycles that the diagnostic test reported a pass and/or a fail.
Powertrain Diagnostic Trouble Code (DTC) Type Definitions
Control Module References for scan tool information
⇒ | If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the fuel pump flow control module. |
⇒ | If less than the specified range, test the 5-volt reference circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the fuel pump flow control module. |
⇒ | If greater than the specified range, test the 5-volt reference circuit for a short to voltage. If the circuit tests normal, replace the fuel pump flow control module. |
⇒ | If less than the specified range, test the signal circuit terminal 1 for a short to ground or an open/high resistance. If the circuit tests normal, replace the fuel pump flow control module. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
Control Module References for FPCM replacement, setup, and programming