Tools Required
J 43244 Relay Puller Pliers
Removal Procedure
- Remove the electrical center cover.
- Locate the cooling fan relay. Refer to
Electrical Center Identification Views
in Wiring Systems to locate the electrical
center where the cooling fan relay exists.
Important:
• | Always note the orientation of the relay. |
• | Make sure the electrical center is secure, as not to put added stress
on the wires or terminals. |
- Using
the J 43244
position the tool
on opposing corners of the cooling fan relay.
Notice: Use J43244 to pull the relay straight out from the electrical
center terminals. The use of pliers or a flat bladed tool could damage the
electrical center.
- Remove the cooling fan relay (2) from the electrical center.
Installation Procedure
- Install
the cooling fan relay in the same position as removed.
- Install the electrical center cover.