Discharge Hose Replacement LLV, LLR
Tools Required
J 39400-A
Halogen Leak Detector
Removal Procedure
- Recover the refrigerant. Refer to
Refrigerant Recovery and Recharging
.
- Remove the generator. Refer to
Generator Replacement
.
- Remove the discharge hose mounting bolt (8) from the A/C compressor.
- Remove the discharge hose (4) from the A/C compressor.
- Remove the discharge hose bolt from the condenser.
- Remove the discharge hose from the condenser.
- Remove the discharge hose from the vehicle.
- Discard all of the used sealing washers. Cap the system openings.
Installation Procedure
- Install the discharge hose to the condenser using new sealing washers. Refer to
Sealing Washer Replacement
.
Notice: Refer to Fastener Notice in the Preface section.
- Install the discharge hose bolt to the condenser.
Tighten
Tighten the bolt to 16 N·m (12 lb ft).
- Install the discharge hose (4) to the A/C compressor using new sealing washers. Refer to
Sealing Washer Replacement
.
- Install the discharge hose mounting bolt (8) to the A/C compressor.
Tighten
Tighten the bolt to 16 N·m (12 lb ft).
- Install the generator. Refer to
Generator Replacement
.
- Evacuate and recharge the A/C system. Refer to
Refrigerant Recovery and Recharging
.
- Leak test the fittings of the component using the
J 39400-A
.