Step | Action | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|
DEFINITION: The temperature control operates with either too much or too little effort. | |||||||||
1 | Were you sent here from Symptoms or another diagnostic table? | Go to Step 2 | |||||||
2 | Is one of the following a concern of the customer:
Does the temperature control operate too freely? | Go to Step 3 | Go to Step 7 | ||||||
3 |
Does the temperature change from cold to hot? | Go to Step 17 | Go to Step 4 | ||||||
4 | Inspect the connections of the temperature control cable. Is the temperature control cable disconnected from the temperature door? | Go to Step 15 | Go to Step 5 | ||||||
5 | Inspect the temperature control cable and linkage at the temperature door, while operating the temperature controls. Does the temperature door move while operating the temperature controls? | Go to Step 22 | Go to Step 6 | ||||||
6 | Inspect the cable casing while operating the temperature controls. Does the cable casing move, instead of the cable, while operating the temperature controls? | Go to Step 19 | Go to Step 16 | ||||||
7 | Inspect the HVAC control assembly for any debris or obstructions that would increase the effort to operate the temperature controls. Are there any obstructions? | Go to Step 21 | Go to Step 8 | ||||||
8 |
Does the HVAC control assembly bind now? | Go to Step 10 | Go to Step 9 | ||||||
9 | With the temperature control cable disconnected:
Does the temperature door bind with the cable disconnected? | Go to Step 20 | Go to Step 10 | ||||||
10 |
Does the HVAC control assembly bind now? | Go to Step 17 | Go to Step 11 | ||||||
11 | With the temperature control cable disconnected at both ends:
Does the temperature control cable bind? | Go to Step 18 | Go to Step 12 | ||||||
12 |
Does the temperature cable still bind? | Go to Step 18 | Go to Step 13 | ||||||
13 | Operate the HVAC control assembly with the temperature control cable disconnected. Does the HVAC control assembly bind now? | Go to Step 17 | Go to Step 14 | ||||||
14 | Reassemble the temperature control system. Is the action complete? | Go to Step 22 | -- | ||||||
15 | Reconnect the temperature control cable to the temperature door linkage install the cable retainers. Is the action complete? | Go to Step 22 | -- | ||||||
16 | Repair the lack of heating or lack of cooling condition. Refer to Diagnostic Starting Point - Heating, Ventilation and Air Conditioning . Is the action complete? | Go to Step 22 | -- | ||||||
17 | Replace the HVAC control assembly. Refer to Heater and Air Conditioning Control Replacement . Is the repair complete? | Go to Step 22 | -- | ||||||
18 | Replace the temperature control cable. Refer to Temperature Control Cable Replacement . Is the repair complete? | Go to Step 22 | -- | ||||||
19 | Secure the temperature control cable casing. Is the action complete? | Go to Step 22 | -- | ||||||
20 | Repair the binding door. Refer to Air Temperature Door Replacement . Is the repair complete? | Go to Step 22 | -- | ||||||
21 | Remove the debris. Is the action complete? | Go to Step 22 | -- | ||||||
22 | Operate the system in order to verify the repair. Did you find and correct the condition? | System OK | Go to Step 2 |