The numbers below refer to the step numbers on the diagnostic table.
The IGN 3 relay, HVAC A fuse and the blower motor are in a series circuit. The test lamp should illuminate if there is no concern with the series circuit.
Probe the ground circuit of the blower motor switch in the HVAC control assembly.
Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The blower motor is inoperative in all speed positions. | |||
1 | Did you perform the HVAC Diagnostic System Check? | Go to Step 2 | |
2 |
Does the blower motor operate in any speed position? | Go to Blower Motor Malfunction | Go to Step 3 |
3 |
Does the test lamp illuminate? | Go to Step 6 | Go to Step 4 |
4 | Probe the HVAC A fuse with a test lamp connected to a good ground. Does the test lamp illuminate? | Go to Step 12 | Go to Step 5 |
5 |
Does the test lamp illuminate? | Go to Step 15 | Go to Step 9 |
6 |
Does the test lamp illuminate? | Go to Step 13 | Go to Step 7 |
Does the test lamp illuminate? | Go to Step 8 | Go to Step 10 | |
Connect a test lamp between the ground circuit of the HVAC control assembly and battery positive voltage circuit. Does the test lamp illuminate? | Go to Step 14 | Go to Step 11 | |
9 | Repair the battery positive circuit of the ignition 3 relay for an open. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 18 | -- |
10 | Repair the blower motor high control circuit of the HVAC control assembly for an open. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 18 | -- |
11 | Test the ground circuit for an open and a high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 18 | Go to Step 14 |
12 | Repair the blower motor supply voltage circuit of the blower motor. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 18 | -- |
13 | Inspect for poor connections at the blower motor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 18 | Go to Step 16 |
14 | Inspect for poor connections at the HVAC control assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 18 | Go to Step 17 |
15 | Replace the ignition 3 relay. Did you complete the replacement? | Go to Step 18 | -- |
16 | Replace the blower motor. Refer to Blower Motor Replacement in Heating Ventilation and Air Conditioning. Did you complete the replacement? | Go to Step 18 | -- |
17 | Replace the HVAC control assembly. Refer to Heater and Air Conditioning Control Replacement . Did you complete the replacement? | Go to Step 18 | -- |
18 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |