Modules connected to the class 2 serial data circuit monitor for serial data communications during normal vehicle operation. Operating information and commands are exchanged among the modules. Connecting a scan tool to the data link connector (DLC) allows communication with the modules for diagnostic purposes. DTCs may be set due to this symptom and during this diagnostic procedure. Complete the diagnostic procedure in order to ensure all the DTCs are diagnosed and cleared from memory.
• | The body control module (BCM) detects that the ignition is ON and sends the appropriate power mode message to the other modules. Therefore, the BCM must be connected to the DLC for any other module to communicate with the scan tool. |
• | When the class 2 serial data circuit: |
- | Is shorted to ground |
- | Is shorted to voltage |
The following DTCs may set:
• | U1300 |
• | U1301 |
• | U1305 |
The numbers below refer to the step numbers on the diagnostic table.
A partial loss of communication in the class 2 serial data circuit uses a different procedure than a total loss of communication of the class 2 serial data circuit.
The following DTCs may be retrieved with a history status. These DTCs are not the cause of the present condition.
• | U1300 |
• | U1301 |
• | U1305 |
A State of Health DTC with a history status may be present along with a U1000 or U1255 with a current status. This indicates that the malfunction occurred when the ignition was ON.
Normal class 2 serial data communication cannot take place until the BCM sends the appropriate power mode message. If the BCM does not send a wake-up message, other modules on the class 2 serial data circuit may not communicate.
Normal class 2 serial data communication cannot take place until the BCM sends the appropriate power mode message. If the BCM does not send a wake-up message, other modules on the class 2 serial data circuit may not communicate.
If there are no current DTCs that begin with the letter "U", the communication concern has been repaired.
The communication concern may have prevented diagnosis of the customer complaint.
Step | Action | Yes | No | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: Data Link Connector Schematics Connector End View Reference: Master Electrical Component List and Inline Harness Connector End Views in Wiring Systems | |||||||||||||||||||||||
1 | Does the scan tool power up? | Go to Step 2 | |||||||||||||||||||||
Does the scan tool communicate with any module on the class 2 serial data circuit? | Go to Step 3 | Go to Step 8 | |||||||||||||||||||||
3 |
Did you record any DTCs in the range of U1000 to U1305? | Go to Step 4 | Go to Step 7 | ||||||||||||||||||||
Are history DTCs U1300, U1301 or U1305 retrieved from any module? | Go to Step 5 | Go to Step 6 | |||||||||||||||||||||
5 |
Important:: Turn ON the ignition, with the engine OFF, when testing for a short to voltage. Use the DMM MIN/MAX function to capture intermittent conditions. Test the class 2 serial data circuit for an intermittent short to ground or an intermittent short to voltage. Refer to the following in Wiring Systems: Did you find and correct the condition? | Go to Step 16 | Go to Step 6 | ||||||||||||||||||||
Are U1000 or U1255 the only DTCs displayed in the previously specified range? | Go to DTC U1000 and U1255 | Go to DTC U1001-U1254 | |||||||||||||||||||||
7 | Diagnose the non communicating module by using the DTC U1001--U1254 Lost Communications with XXX procedure for the module which is not communicating. The DTC U1001--U1254 Lost Communications with XXX procedure will determine which module is not communicating. Refer to DTC U1001-U1254 . Did you complete the action? | Go to Control Module References in Body Control System for the applicable Diagnostic System Check | -- | ||||||||||||||||||||
8 |
Did you find and correct the condition? | Go to Control Module References in Body Control System for the applicable Diagnostic System Check | Go to Step 9 | ||||||||||||||||||||
9 | Test the signal ground circuits of the DLC for an open or high resistance. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Control Module References in Body Control System for the applicable Diagnostic System Check | Go to Step 10 | ||||||||||||||||||||
Does the scan tool communicate with the BCM? | Go to Step 12 | Go to Step 11 | |||||||||||||||||||||
11 |
Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 16 | Go to Step 14 | ||||||||||||||||||||
Important: The BCM must remain connected to the DLC. Use the appropriate jumper if needed. Using the correct terminal adapter and jumper wire at the splice pack, perform the following in order to determine which class 2 serial data circuit or module is causing the concern:
Did you complete the action? | Go to Step 13 | -- | |||||||||||||||||||||
13 |
Did you find and correct the condition? | Go to Step 16 | Go to Step 14 | ||||||||||||||||||||
14 | Inspect for poor connections and terminal tension at the harness connector of the suspect module. Refer to Testing for Intermittent Conditions and Poor Connections and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 16 | Go to Step 15 | ||||||||||||||||||||
15 |
Important: Perform the module programming or setup procedure if required. Replace the suspect module. Refer to Control Module References in Body Control System for the appropriate Repair Instructions for module replacement. Did you complete the replacement? | Go to Step 16 | -- | ||||||||||||||||||||
16 |
Important: The scan tool may require a power up reset before communication will occur due to a short on the class 2 serial data circuit. Turn off or disconnect the scan tool before you display DTCs. Did your record any DTCs which begin with a letter "U" and with a current status? | Go to Step 18 | Go to Step 17 | ||||||||||||||||||||
Did you record any DTCs which do not begin with a letter "U"? | Go to Step 18 | Go to Step 19 | |||||||||||||||||||||
Diagnose the DTCs as directed by the diagnostic procedures for the particular module or concern. Did you complete the action? | Go to Step 19 | -- | |||||||||||||||||||||
19 | Did you diagnose all of the DTCs? | Go to Step 20 | Go to Step 18 | ||||||||||||||||||||
20 | Clear the DTCs using the scan tool. Did you complete the action? | Go to Control Module References in Body Control System for the applicable Diagnostic System Check | -- |