The endgate control module supplies voltage for the endgate latch relay coil control circuit to the endgate latch relay. This output is used to energize the endgate latch relay when an endgate swing latch or drop latch request has been made. If the endgate module detects an open or short to ground on the endgate latch relay coil control circuit when a swing latch or drop latch request is made, a DTC is set.
This diagnostic procedure supports the following DTC:
DTC B3745 Endgate Latch Relay Control Circuit
• | The endgate module detects an open or short to ground on the endgate latch relay coil control circuit. |
• | Condition must be present when a swing latch request or drop latch request is made. |
• | Stores a current DTC B3745 in endgate module memory. |
• | Stores a history DTC B3745 in endgate module memory. |
• | The endgate module will ignore the swing latch or drop latch request. |
• | The endgate module no longer detects a current DTC B3745 in endgate module memory. |
• | The DTC is cleared using a scan tool. |
• | The following conditions may cause an intermittent malfunction: |
- | There is an intermittent open in a endgate latch relay coil control circuit. |
- | The endgate latch relay coil is open internally. |
• | If the DTC does not reset after the code is cleared, then the problem may be intermittent. Refer to Testing for Intermittent Conditions and Poor Connections . |
The number below refers to the step number on the diagnostic table.
Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Body Rear End Schematics Connector End View Reference: Body Rear End Connector End Views | |||
1 | Did you perform the Diagnostic System Check - Vehicle? | Go to Step 2 | |
Does the test lamp illuminate? | Go to Step 4 | Go to Step 3 | |
3 | Test the endgate latch relay coil control circuit for a short to ground or an open. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 8 | Go to Step 5 |
4 | Inspect for poor connections at the harness connector of the endgate latch relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 8 | Go to Step 5 |
5 | Inspect for poor connections at the harness connector of the endgate module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 8 | Go to Step 7 |
6 | Replace the endgate latch relay. Refer to Endgate Wiring Harness Replacement . Did you complete the replacement? | Go to Step 8 | -- |
7 |
Did you complete the replacement? | Go to Step 8 | -- |
8 |
Does the DTC reset? | Go to Step 2 | System OK |