Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The auxiliary mode doors cannot be adjusted. | |||
1 | Did you perform the HVAC Diagnostic System Check? | Go to Step 2 | |
2 |
Does the scan tool display DTC B0145, B0428, or B3531? | Go to Step 3 | |
3 |
Does the front auxiliary blower motor operate in any of the speed positions? | Go to Step 4 | |
4 | Does the auxiliary blower motor operate at the desired speed? | Go to Step 5 | |
5 |
Does both the Console Mode Door and the Mode Door Actual parameters count value change? | Go to Step 8 | Go to Step 6 |
6 | Inspect for poor connections at the harness connector of the auxiliary HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 8 | Go to Step 7 |
7 | Replace the auxiliary HVAC control module. Refer to Auxiliary Heater and Air Conditioning Control Module Replacement . Did you complete the replacement? | Go to Step 8 | -- |
8 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |
• | When the primary HVAC system is placed to the defrost position, the auxiliary HVAC controls are disabled. |
• | The auxiliary blower motor is only enabled when in medium and high speeds. When low speed is selected the primary HVAC blower forces air through the auxiliary system. The air speed will vary depending on the speed of the primary blower motor. |
Step | Action | Value(s) | Yes | No | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: Air does not flow correctly from the auxiliary air distribution outlets. | ||||||||||||||
1 | Did you perform the HVAC Diagnostic System Check? | -- | Go to Step 2 | |||||||||||
2 |
Is the auxiliary blower motor OFF? | -- | Go to Step 3 | |||||||||||
3 |
Does the auxiliary blower motor operate in both speed positions? | -- | Go to Step 4 | |||||||||||
4 | Does the auxiliary blower motor operate in each speed position? | -- | Go to Step 5 | |||||||||||
5 |
Does the scan tool indicate that the Mode Switch parameter changes state? | -- | Go to Step 6 | Go to Step 12 | ||||||||||
6 |
Does the test lamp illuminate? | -- | Go to Step 7 | Go to Step 13 | ||||||||||
7 | Test the ground circuit of the auxiliary mode actuator for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 16 | Go to Step 8 | ||||||||||
8 |
Does the voltage measure near the specified values? |
| Go to Step 10 | Go to Step 9 | ||||||||||
9 | Test the auxiliary mode door control circuit of the auxiliary mode actuator for an open, a short to ground or a short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 16 | Go to Step 12 | ||||||||||
10 | Inspect the auxiliary mode door and the auxiliary mode actuator for the following:
Did you find and correct the condition? | -- | Go to Step 16 | Go to Step 11 | ||||||||||
11 | Inspect for poor connections at the harness connector of the auxiliary mode actuator. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 16 | Go to Step 14 | ||||||||||
12 | Inspect for poor connections at the harness connector of the auxiliary HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 16 | Go to Step 15 | ||||||||||
13 | Repair the ignition 3 voltage circuit of the auxiliary mode actuator. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | Go to Step 16 | -- | ||||||||||
14 | Replace the auxiliary mode actuator. Refer to Mode Actuator Replacement - Console . Did you complete the replacement? | -- | Go to Step 16 | -- | ||||||||||
15 | Replace the auxiliary HVAC control module. Refer to Auxiliary Heater and Air Conditioning Control Module Replacement . Did you complete the replacement? | -- | Go to Step 16 | -- | ||||||||||
16 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |