Removal Procedure


    Object Number: 735936  Size: SH
  1. Remove the HVAC module assembly. Refer to HVAC Module Assembly Replacement .
  2. Remove the floor air outlet duct retaining screws (2, 3, 4).
  3. Remove the RH side floor air outlet duct (1).

Installation Procedure


    Object Number: 735936  Size: SH
  1. Install the floor air outlet duct (1) into position.
  2. Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.

  3. Install the floor air outlet duct retaining screws (2, 3, 4).
  4. Tighten
    Tighten the screws to 1.9 N·m (17 lb in).

  5. Install the HVAC module assembly. Refer to HVAC Module Assembly Replacement .