Removal Procedure
- Remove the I/P carrier. Refer to
Instrument Panel Carrier Replacement.
- Remove the screws from the mode actuator.
- Remove the mode actuator.
- Remove screws in order to separate the defroster/mode outlet cover (2) from the HVAC module assembly (1).
- Remove the mode door (1) from the heater module.
Installation Procedure
- Install the mode door (1) to the HVAC module assembly.
- Install the defroster/mode outlet cover.
- Install the defroster/mode outlet cover screws to the HVAC module assembly (1).
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the screws to assemble the defroster/mode outlet to the HVAC module assembly.
Tighten
Tighten the screws to 1.9 N·m (18 lb in).
- Install the mode actuator.
- Install the screws to the mode actuator.
Tighten
Tighten the screws to 1.9 N·m (18 lb in).
- Install the I/P carrier. Refer to
Instrument Panel Carrier Replacement.