Removal Procedure
- Remove the negative battery cable. Refer to
Battery Negative Cable Replacement.
- Mark the location of the negative battery cable clips and remove the clips from the cable.
- Remove the tape securing the generator battery current sensor to the negative battery cable.
- Squeeze the negative battery cable branches together.
Important: Note the orientation of the generator battery current sensor prior to removal.
- Slide the generator battery current sensor (1) off of the negative battery cable.
Installation Procedure
- Squeeze the negative battery cable together.
Important: Ensure the generator battery current sensor is installed in the correct direction and location on the negative battery cable.
- Slide the NEW generator battery current sensor (1) up onto the negative battery cable and insert the tab under the negative battery cable terminal cover.
- Wrap electrical tape around the generator battery current sensor leg in order to secure the sensor to the negative battery cable.
- Install the negative battery cable clips to the cable to the locations previously marked during removal.
- Install the negative battery cable. Refer to
Battery Negative Cable Replacement.