GM Service Manual Online
For 1990-2009 cars only

Diagnostic Instructions

    • Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure.
    • Review Strategy Based Diagnosis for an overview of the diagnostic approach.
    •  Diagnostic Procedure Instructions provides an overview of each diagnostic category.

DTC Descriptors

DTC B0229: Recirc Position Feedback Circuit Range/Performance

DTC B0248: Air Flow Control 3 Circuit

DTC B0263: Air Flow Control 6 Circuit

DTC B0268: Air Flow Control 7 Circuit

DTC B0408: Temperature Control 1 Circuit

DTC B0414: Temperature Control 1 Feedback Circuit Range/Performance

DTC B0418: Temperature Control 2 Circuit

DTC B0424: Temperature Control 2 Feedback Circuit Range/Performance

DTC B3761: Air Flow Control 3 Feedback Circuit

DTC B3770: Air Flow Control 6 Feedback Circuit

Diagnostic Fault Information

Circuit

Short to Ground

Open/High Resistance

Short to Voltage

Signal Performance

Recirculation 5-Volt Reference

B0229, B0414, B0424, B3761, B3770, B0248, B0263, B0268, B0408, B0418

B0229

B0229, B0414, B0424, B3761, B3770, B0248, B0263, B0268, B0408, B0418

B0229

Recirculation Door Position Signal

B0229

B0229

B0229

B0229

Recirculation Door Control

B0229

B0229

B0229

B0229

Ignition Voltage

--

B0229

--

B0229

Recirculation Low Reference

--

B0229

--

B0229

Driver Air Temperature 5-Volt Reference

B0229, B0414, B0424, B3761, B3770, B0248, B0263, B0268, B0408, B0418

B0414

B0229, B0414, B0424, B3761, B3770, B0248, B0263, B0268, B0408, B0418

B0414

Driver Air Temperature Door Position Signal

B0414

B0414

B0414

B0414

Driver Air Temperature Door Control

B0414

B0414

B0414

--

Driver Air Temperature Door Ignition Voltage

--

B0414

--

--

Driver Air Temperature Low Reference

--

B0413 05

--

--

Passenger Air Temperature 5-Volt Reference

B0229, B0414, B0424, B3761, B3770, B0248, B0263, B0268, B0408, B0418

B0424

B0229, B0414, B0424, B3761, B3770, B0248, B0263, B0268, B0408, B0418

B0424

Passenger Air Temperature Door Position Signal

B0424

B0424

B0424

B0424

Passenger Air Temperature Door Control

B0424

B0424

B0424

B0424

Passenger Air Temperature Door Ignition Voltage

--

B0424

--

--

Passenger Air Temperature Low Reference

--

B0424

--

--

Mode 5-Volt Reference

B0229, B0414, B0424, B3761, B3770, B0248, B0263, B0268, B0408, B0418

B3770

B0229, B0414, B0424, B3761, B3770, B0248, B0263, B0268, B0408, B0418

B3770

Mode Door Position Signal

B3770

B3770

B3770

B3770

Mode Door Control

B3770

B3770

B3770

B3770

Mode Door Ignition Voltage

--

B3770

--

--

Mode Low Reference

--

B3770

--

--

Circuit/System Description

The HVAC control module controls the HVAC door actuators to regulate the airflow through the HVAC system. Each actuator consists of an electric motor and a potentiometer. The module supplies a low reference and 5-volt reference source voltage to the potentiometer. The HVAC control module monitors the voltage drop across the potentiometer on the door position signal circuit. When the actuator shaft rotates, the voltage on the door position signal circuit changes. The control circuit uses either a 0, 2.5 or 5-volt signal to command the actuator movement. When the actuator is at rest, the control circuit value is 2.5 volts. A 0 or 5-volt control signal commands the actuator movement in opposite directions.

    • B0229 is for the recirculation actuator.
    • B0414 is for the left air temperature actuator.
    • B0424 is for the right air temperature actuator.
    • B3761 is for the defrost actuator.
    • B3770 is for the mode actuator.
    • B0248 is for the defrost actuator.
    • B0263 is for the mode actuator.
    • B0268 is for the recirculation actuator.
    • B0408 is for the left air temperature actuator.
    • B0418 is for the right air temperature actuator.

Conditions for Running the DTC

    • The ignition is ON.
    • The HVAC module is ON.

Conditions for Setting the DTC

The actual door position differs from the commanded door position by more than 4 counts or the HVAC control module detects the door position signal circuit is less than 3 counts or greater than 253 counts.

Action Taken When the DTC Sets

The control circuit is deactivated for the appropriate actuator.

Conditions for Clearing the DTC

    • The DTC becomes history when the HVAC control module no longer detects the condition that set the DTC.
    • The history DTC will clear after 50 fault-free ignition cycles.

Reference Information

Schematic Reference

HVAC Schematics

Connector End View Reference

Component Connector End Views

Description and Operation

    •  Air Delivery Description and Operation
    •  Air Temperature Description and Operation

Electrical Information Reference

    •  Circuit Testing
    •  Connector Repairs
    •  Testing for Intermittent Conditions and Poor Connections
    •  Wiring Repairs

Scan Tool Reference

Control Module References for scan tool information

Circuit/System Verification

Ignition ON, command the appropriate actuator in both directions with a scan tool. The scan tool door position parameter reading should be between 3 and 253 counts.

Circuit/System Testing

  1. Ignition OFF, disconnect the harness connector at the appropriate actuator.
  2. Ignition OFF, test for less than 1 ohm between the low reference circuit and ground.
  3. If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the HVAC control module.
  4. Ignition ON, test for 4.8-5.2 volts between the 5-volt reference circuit and ground.
  5. If less than the specified range, test the 5-volt reference circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the HVAC control module.
    If greater than the specified range, test the 5-volt reference circuit for a short to voltage. If the circuit tests normal, replace the HVAC control module.
  6. Verify the appropriate scan tool parameter is less than 4 counts.
  7. If greater than the specified range, test the signal circuit for a short to ground. If the circuit tests normal, replace the HVAC control module.
  8. Install a 3-amp fused jumper wire between the signal circuit and the low reference circuit terminal. Verify the appropriate scan tool parameter is greater than 250 counts.
  9. If less than the specified range, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the HVAC control module.
  10. Ignition ON, verify that a test lamp illuminates between the ignition 3 circuit and ground.
  11. If the test lamp does not illuminate, test the ignition 3 circuit for a short to ground an open/high resistance.
  12. Install a DMM between the actuator control circuit and ground. While monitoring the DMM use the scan tool to command the appropriate actuator from one direction to the other. If the voltage on the control circuit should move from 0 volts in one direction to 5 volts in the other direction and 2.5 volts in the at rest state.
  13. If the voltage does not change, test the control circuit for an open, short to voltage or short to ground. If circuit tests normal replace the HVAC control module.
  14. If all circuits test normal, test or replace the actuator.

Repair Instructions

Perform the Diagnostic Repair Verification after completing the diagnostic procedure.

    •  Recirculation Actuator Replacement
    •  Mode Actuator Replacement
    •  Temperature Valve Actuator Replacement - Left Side
    •  Temperature Valve Actuator Replacement - Right Side
    •  Defroster Valve Actuator Replacement
    •  Control Module References for HVAC control module and HVAC auxiliary control module or rear seat audio (RSA) replacement, setup, and programming