Application | Specification | |
---|---|---|
Metric | English | |
A/C Compressor Mounting Bolt (Gasoline Engine) | 145 N·m | 33 lb ft |
BAT Terminal Nut (21-SI 200 Generator) | 20 N·m | 14 lb ft |
Battery Positive Cable Nut (PG-260) | 10 N·m | 89 lb in |
Battery Positive Cable Nut (37-MT/300) | 30 N·m | 22 lb ft |
Battery Positive Cable Nut (37-MT/350) | 30 N·m | 22 lb ft |
Battery Positive Cable to Starter Nut (Gasoline Engine) | 10 N·m | 89 lb in |
Battery Positive Cable to Starter Nut (7.2L Diesel Engine) | 30 N·m | 22 lb ft |
Battery Side Post Terminal Bolt | 17 N·m | 13 lb ft |
Battery Top Bar Nut | 17 N·m | 13 lb ft |
Battery Top Post Terminal Nut | 23 N·m | 17 lb ft |
Coil Bracket Bolt | 28 N·m | 17 lb ft |
Coil Bracket Nut | 33 N·m | 24 lb ft |
Commutator End Frame Ground Cable Nut (37-MT/300) | 30 N·m | 22 lb ft |
Commutator End Frame Ground Cable Nut (37-MT/350) | 30 N·m | 22 lb ft |
Distributor Bolt | 27 N·m | 20 lb ft |
Drive Housing to Lever Housing Screws (37-MT) | 24 N·m | 18 lb ft |
End Frame Bolts (37-MT) | 5.6 N·m | 50 lb in |
Engine Temperature Sensor Bolt | 40 N·m | 30 lb ft |
Ether Capsule Bracket Clamp | 2 N·m | 18 lb in |
Ether Injector Control Valve and Bracket Mounting Bolt | 25 N·m | 18 lb ft |
Ether Injector Tube Connector Nut | 4 N·m | 35 lb in |
Ether Injector Tube Connector to Ether Injector Control Valve Assembly | 3 N·m | 27 lb in |
Ether Tube Connector to Ether Injector Nozzle | 30 N·m | 22 lb ft |
Field Connector to Field Terminal Screw (37-MT) | 3.4 N·m | 30 lb in |
Field Connector to Solenoid Screw (37-MT) | 3.4 N·m | 30 lb in |
Field Frame Ground Cable Nut (37-MT/350) | 30 N·m | 22 lb ft |
Frame to Engine Cable, Engine Side Bolt (Gasoline Engine) | 30 N·m | 22 lb ft |
Frame to Engine Cable, Frame Side Nut (Gasoline Engine) | 30 N·m | 22 lb ft |
Frame to Starter Cable, Frame Side (7.2L Diesel Engine) | 28 N·m | 21 lb ft |
Frame to Starter Cable, Starter Side (7.2L Diesel Engine) | 30 N·m | 22 lb ft |
Generator Adjusting Bracket Mounting Bolt (7.2L Diesel Engine) | 73 N·m | 54 lb ft |
Generator Ground Strap Bolt (Gasoline Engine) | 17 N·m | 13 lb ft |
Generator Ground Strap Bolt (7.2L Diesel Engine) | 11 N·m | 97 lb in |
Generator Ground Strap to Engine Bolt (Gasoline Engines) | 17 N·m | 13 lb ft |
Generator Ground Strap to Engine Bolt (7.2L Diesel Engine) | 32 N·m | 24 lb ft |
Generator Ground Strap to Generator Nut (Gasoline Engine) | 45 N·m | 33 lb ft |
Generator Ground Strap to Generator Bolt (7.2L Diesel Engine) | 11 N·m | 97 lb in |
Generator Indicator Terminal Nut (7.2L Diesel Engine) | 2 N·m | 18 lb in |
Generator Mounting (Bottom) Bolt (Gasoline Engine) | 45 N·m | 33 lb ft |
Generator Mounting (Bottom) Bolt (7.2L Diesel Engine) | 71 N·m | 52 lb ft |
Generator Mounting (Rear) Bolt (Gasoline Engine) | 40 N·m | 30 lb ft |
Generator Mounting (Top) Bolt (Gasoline Engine) | 45 N·m | 33 lb ft |
Generator Mounting (Top) Bolt (7.2L Diesel Engine) | 88 N·m | 65 lb ft |
Generator Mounting Bracket Bolt (Gasoline Engine) | 50 N·m | 37 lb ft |
Generator Output Terminal Nut (All Engines) | 20 N·m | 14 lb in |
Generator Rear Mounting Bracket Bolt (Gasoline Engine) | 50 N·m | 37 lb ft |
Generator Relay Terminal Nut (7.2L Diesel Engine) | 2 N·m | 18 lb in |
Generator Shaft Nut (Gasoline Engine) | 100 N·m | 75 lb ft |
Generator Shaft Nut (7.2L Diesel Engine) | 100 N·m | 75 lb ft |
Generator Through Bolts (21-SI 200 Generator) | 5.5 N·m | 50 lb in |
Ground Lead to Commutator End Terminal Nut (37-MT) | 30 N·m | 22 lb ft |
Ground Lead to Solenoid Terminal Nut (37-MT) | 3 N·m | 27 lb in |
Heat Shield Bolt (PG-260) | 12 N·m | 106 lb in |
Heat Shield (Rear) Bolt (PG-260) | 55 N·m | 48 lb ft |
Hold Down Bolt (Side Post) | 23 N·m | 17 lb ft |
Lever Housing to Field Frame Bolts (37-MT) | 20 N·m | 15 lb ft |
Negative Battery Cable Extension to Frame Bolt | 33 N·m | 24 lb ft |
Negative Battery Cable to Frame Bolt | 30 N·m | 22 lb ft |
Positive Cable Post Nut (Nylon)(CS-130 Generator) | 7 N·m | 62 lb in |
Positive Cable Post Nut (Free Running)(CS-130 Generator) | 12 N·m | 106 lb in |
Positive Cable Post Nut (CS-130D Generator) | 18 N·m | 13 lb ft |
Positive Cable Post Nut (CS-144 Generator) | 18 N·m | 13 lb ft |
Pulley Nut (CS-144 Generator) | 100 N·m | 74 lb ft |
Pulley Nut (21-SI 200 Generator) | 100 N·m | 74 lb ft |
Rectifier Bridge Ground Screws (21-SI 200 Generator) | 3 N·m | 25 lb in |
Rectifier Bridge Insulator Screw (21-SI 200 Generator) | 2.5 N·m | 22 lb in |
Regulator Nut (21-SI 200 Generator) | 2.5 N·m | 22 lb in |
Relay Mounting Screw | 8 N·m | 71 lb in |
Relay Terminal Nuts (21-SI 200 Generator) | 2.5 N·m | 22 lb in |
Solenoid Mounting Screws (37-MT) | 18 N·m | 13 lb ft |
SRE Retainer Screws (21-SI 200 Generator) | 3 N·m | 26 lb in |
Starter Motor Bolt (PG-260) | 40 N·m | 30 lb ft |
Starter Motor Bolt (37-MT/300) | 70 N·m | 52 lb ft |
Starter Motor Bolt (37-MT/350) | 70 N·m | 52 lb ft |
Starter Solenoid Nut (PG-260) | 2 N·m | 18 lb in |
Starter Solenoid Nut (37-MT/300) | 3 N·m | 27 lb in |
Starter Solenoid Nut (37-MT/350) | 3 N·m | 27 lb in |
Stator Lead to Rectifier Bridge Nuts (21-SI 200 Generator) | 2.5 N·m | 22 lb in |
Through Bolts (28-MT) | 8.5 N·m | 75 lb in |
Vacuum Pump Mounting Bolt | 25 N·m | 18 lb ft |