Problem | Action | ||||||
---|---|---|---|---|---|---|---|
Excessive air brake dryer purge valve leakage is evident. | Inspect for excessive leakage with the air compressor loaded. Apply a soap solution on the purge valve exhaust. If the leakage is excessive, overhaul or replace the air brake dryer. | ||||||
The governor is faulty. |
| ||||||
The purge control line is connected to one of the following components:
| Connect the control line to the unloader port of the governor. | ||||||
A fuse is blown. | Test the electrical circuit. Air Brake System Schematic References . | ||||||
The inlet and the outlet air connections are reversed. | Connect the lines properly. | ||||||
The check valve between the air brake dryer and the supply reservoir is faulty. |
| ||||||
The discharge line is kinked or blocked. | Clean or replace the line as needed. | ||||||
Excessive bends in the discharge line cause the water to collect and freeze. | Correct the discharge line routing. | ||||||
Excessive system leakage is evident. | Inspect for system leakage. Repair or replace parts as needed. |