GM Service Manual Online
For 1990-2009 cars only

Exhaust Gas Recirculation Valve Replacement 6.0L

Removal Procedure

Important: Do not try to disassemble the exhaust gas recirculation (EGR) valve. Service the valve only as a complete assembly.

Important: Carefully note the position of the EGR valve before removal. Do not rotate the EGR valve 180 degrees.

  1. Remove the intake duct. Refer to XXX.

  2. Object Number: 260097  Size: SH
  3. Disconnect the EGR electrical connector.
  4. Remove the valve to flange attaching fasteners.
  5. Notice: The EGR valve is an electrical component. Soaking the EGR valve in a liquid cleaner or a solvent causes damage to the valve.

  6. Remove the EGR valve.
  7. Remove the flange gasket.
  8. Clean the EGR valve gasket surface.

Installation Procedure


    Object Number: 260097  Size: SH
  1. Install the new flange gasket
  2. Install the EGR valve.
  3. Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.

  4. Install the valve to flange fasteners.
  5. Tighten

        • Tighten the fasteners the first time to 10 N·m (89 lb in) each.
        • Tighten the fasteners a final time to 25 N·m (18 lb ft) each.
  6. Connect the electrical connector.
  7. Install Intake duct. Refer to XXX.