GM Service Manual Online
For 1990-2009 cars only

Auxiliary Blower Motor Inoperative W/Sunroof or Heat Only

Test Description

The numbers below refer to the step numbers on the diagnostic table.

  1. This step tests for auxiliary blower motor operation in any speed setting.

  2. This step determines if the malfunction is in the control side of the system.

  3. Test both the auxiliary HVAC control assembly chassis ground circuit and ground loop circuit.

Step

Action

Yes

No

Schematic Reference: HVAC Schematics

DEFINITION: The auxiliary blower motor is inoperative in all speed positions.

1

Did you review the auxiliary HVAC operation and perform the necessary inspections?

Go to Step 2

Go to Symptoms - HVAC Systems - Manual

2

  1. Turn ON the ignition, with the engine OFF.
  2. Place the auxiliary blower motor switch in each speed position.

Does the auxiliary blower motor operate in each speed position?

Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems

Go to Step 3

3

  1. Turn OFF the ignition.
  2. Disconnect the auxiliary blower motor.
  3. Turn ON the ignition, with the engine OFF.
  4. Set the auxiliary blower motor switch to operate at minimum speed.
  5. Connect a test lamp between the auxiliary blower motor supply circuit and a good ground.

Does the test lamp illuminate?

Go to Step 4

Go to Step 6

4

Connect a test lamp between the auxiliary blower motor supply circuit and the auxiliary blower motor ground circuit.

Does the test lamp illuminate?

Go to Step 11

Go to Step 5

5

Test the ground circuit of the auxiliary blower motor resistor assembly for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems.

Did you find and correct the condition?

Go to Step 18

Go to Step 12

6

  1. Turn OFF the ignition.
  2. Disconnect the auxiliary blower motor resistor assembly connectors.
  3. Turn ON the ignition, with the engine OFF.
  4. Probe the auxiliary blower motor resistor assembly ignition 3 voltage circuit with a test lamp that is connected to a good ground.

Does the test lamp illuminate?

Go to Step 7

Go to Step 13

7

Probe the auxiliary blower motor resistor assembly battery positive voltage circuit with a test lamp that is connected to a good ground.

Does the test lamp illuminate?

Go to Step 8

Go to Step 14

8

  1. Set the auxiliary blower motor switch to operate at minimum speed.
  2. Probe the auxiliary blower motor low speed control circuit with a test lamp that is connected to battery positive voltage.

Does the test lamp illuminate?

Go to Step 12

Go to Step 9

9

Test the auxiliary HVAC control assembly ground circuits for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems.

Did you find and correct the condition?

Go to Step 18

Go to Step 10

10

Inspect for poor connections at the harness connector of the auxiliary HVAC control assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems.

Did you find and correct the condition?

Go to Step 18

Go to Step 15

11

Inspect for poor connections at the harness connector of the auxiliary blower motor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems.

Did you find and correct the condition?

Go to Step 18

Go to Step 16

12

Inspect for poor connections at the harness connectors of the auxiliary blower motor resistor assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems.

Did you find and correct the condition?

Go to Step 18

Go to Step 17

13

Repair the ignition 3 voltage circuit of the auxiliary blower motor resistor assembly. Refer to Wiring Repairs in Wiring Systems.

Did you complete the repair?

Go to Step 18

--

14

Repair the battery positive voltage circuit of the auxiliary blower motor resistor assembly. Refer to Wiring Repairs in Wiring Systems.

Did you complete the repair?

Go to Step 18

--

15

Replace auxiliary HVAC control assembly. Refer to Auxiliary Heater and Air Conditioning Control Replacement - Front or Auxiliary Heater and Air Conditioning Control Replacement - Rear .

Did you complete the replacement?

Go to Step 18

--

16

Replace auxiliary blower motor. Refer to Auxiliary Blower Motor Replacement in Heating, Ventilation and Air Conditioning.

Did you complete the replacement?

Go to Step 18

--

17

Replace auxiliary blower motor resistor assembly. Refer to Auxiliary Blower Motor Resistor Replacement in Heating, Ventilation and Air Conditioning.

Did you complete the replacement?

Go to Step 18

--

18

Operate the system in order to verify the repair.

Did you correct the condition?

System OK

Go to Step 2

Auxiliary Blower Motor Inoperative W/O Sunroof

Test Description

The numbers below refer to the step numbers on the diagnostic table.

  1. This step tests for auxiliary blower motor operation in any speed setting.

  2. This step determines if the malfunction is in the control side of the system.

  3. Test both the rear auxiliary HVAC control assembly chassis ground circuit and the ground circuit between the front and rear HVAC control assemblies.

Step

Action

Yes

No

Schematic Reference: HVAC Schematics

DEFINITION: The auxiliary blower motor is inoperative in all speed positions.

1

Did you review the auxiliary HVAC operation and perform the necessary inspections?

Go to Step 2

Go to Symptoms - HVAC Systems - Manual

2

  1. Turn ON the ignition, with the engine OFF.
  2. Operate both the front and rear auxiliary blower motor switches in each speed position.

Does the auxiliary blower motor operate in each speed position from both the front and rear blower motor switches?

Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems

Go to Step 3

3

  1. Turn OFF the ignition.
  2. Disconnect the auxiliary blower motor.
  3. Turn ON the ignition, with the engine OFF.
  4. Set the front auxiliary blower motor switch to operate at minimum speed.
  5. Connect a test lamp between the auxiliary blower motor supply circuit and a good ground.

Does the test lamp illuminate?

Go to Step 4

Go to Step 6

4

Connect a test lamp between the auxiliary blower motor supply circuit and the auxiliary blower motor ground circuit.

Does the test lamp illuminate?

Go to Step 12

Go to Step 5

5

Test the ground circuit of the auxiliary blower motor resistor assembly for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems.

Did you find and correct the condition?

Go to Step 21

Go to Step 13

6

  1. Turn OFF the ignition.
  2. Disconnect the auxiliary blower motor resistor assembly connectors.
  3. Turn ON the ignition, with the engine OFF.
  4. Probe the auxiliary blower motor resistor assembly ignition 3 voltage circuit with a test lamp that is connected to a good ground.

Does the test lamp illuminate?

Go to Step 7

Go to Step 15

7

Probe the auxiliary blower motor resistor assembly battery positive voltage circuit with a test lamp that is connected to a good ground.

Does the test lamp illuminate?

Go to Step 8

Go to Step 16

8

  1. Set the front auxiliary blower motor switch to operate at minimum speed.
  2. Probe the auxiliary blower motor low speed control circuit with a test lamp that is connected to battery positive voltage.

Does the test lamp illuminate?

Go to Step 13

Go to Step 9

9

  1. Turn OFF the ignition.
  2. Disconnect the front auxiliary HVAC control assembly
  3. Probe the front auxiliary HVAC control assembly ground circuit with a test lamp that is connected to battery positive voltage.

Does the test lamp illuminate?

Go to Step 14

Go to Step 10

10

Test the auxiliary HVAC control assembly ground circuits for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems.

Did you find and correct the condition?

Go to Step 21

Go to Step 11

11

Inspect for poor connections at the harness connector of the rear auxiliary HVAC control assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems.

Did you find and correct the condition?

Go to Step 21

Go to Step 17

12

Inspect for poor connections at the harness connector of the auxiliary blower motor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems.

Did you find and correct the condition?

Go to Step 21

Go to Step 19

13

Inspect for poor connections at the harness connectors of the auxiliary blower motor resistor assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems.

Did you find and correct the condition?

Go to Step 21

Go to Step 20

14

Inspect for poor connections at the harness connector of the front auxiliary HVAC control assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems.

Did you find and correct the condition?

Go to Step 21

Go to Step 18

15

Repair the ignition 3 voltage circuit of the auxiliary blower motor resistor assembly. Refer to Wiring Repairs in Wiring Systems.

Did you complete the repair?

Go to Step 21

--

16

Repair the battery positive voltage circuit of the auxiliary blower motor resistor assembly. Refer to Wiring Repairs in Wiring Systems.

Did you complete the repair?

Go to Step 21

--

17

Replace rear auxiliary HVAC control assembly. Refer to Auxiliary Heater and Air Conditioning Control Replacement - Rear .

Did you complete the replacement?

Go to Step 21

--

18

Replace front auxiliary HVAC control assembly. Refer to Auxiliary Heater and Air Conditioning Control Replacement - Front .

Did you complete the replacement?

Go to Step 21

--

19

Replace auxiliary blower motor. Refer to Auxiliary Blower Motor Replacement in Heating, Ventilation and Air Conditioning.

Did you complete the replacement?

Go to Step 21

--

20

Replace auxiliary blower motor resistor assembly. Refer to Auxiliary Blower Motor Resistor Replacement in Heating, Ventilation and Air Conditioning.

Did you complete the replacement?

Go to Step 21

--

21

Operate the system in order to verify the repair.

Did you correct the condition?

System OK

Go to Step 2