Table 1: | ECC Scan Tool Output Controls |
Table 2: | PCM Scan Tool Output Controls |
Scan Tool Output Control | Additional Menu Selection(s) | Description |
---|---|---|
Rear defogger | Miscellaneous | The scan tool displays Commanded State: None, Off or On. The selection activates or deactivates the rear defrost. |
A/C Request | Miscellaneous | The scan tool displays Commanded State: None, Off or On. The selection activates or deactivates the A/C request signal. |
Recirculation Mode | Miscellaneous | The scan tool displays Commanded State: None, Off or On. The selection activates or deactivates the recirc light and drives the recirculation door to the recirculation position. |
Outside Air Mode | Miscellaneous | The scan tool displays Commanded State: None, Off or On. The selection activates or deactivates the recirc light and drives the recirculation door to the outside air position. |
Air Inlet Door | Motor/Actuator tests | The scan tool displays Outside or Recirc selections. The selection drives the actuator to its min or max stops. |
Blower Motor | Motor/Actuator tests | The scan tool displays Commanded State: None, Off or On. This function allows you to command the blower motor to its maximum (100%) or minimum (0%) speeds. |
Blower Motor Auxiliary | Motor/Actuator tests | The scan tool displays Commanded State: None, Off or On. This function allows you to command the auxiliary blower motor to its maximum (100%) or minimum (0%) speeds. |
Mode Door Position | Motor/Actuator tests | The scan tool displays Defrost or Panel selections. The selection drives the actuator to its min or max stops. |
Auxiliary Mode Door | Motor/Actuator tests | The scan tool displays Upper Outlets or Floor selections. The selection drives the actuator to its min or max stops. |
Instant OAT Update | Miscellaneous | The scan tool displays Commanded State: None, Off or On. Updates the ECC outside air temperature input to the current raw value. |
Mix Motor | Motor/Actuator tests | The scan tool displays Commanded State: None, Off or On. The selection drives the temperature actuator to its min or max stops. |
Auxiliary Mix door | Motor/Actuator tests | The scan tool displays Commanded State: None, Off or On. The selection drives the auxiliary temperature actuator to its min or max stops. |
Set up new HVAC | Set up new HVAC | This function allows the control module to learn what auxiliary system the vehicle is equipt with. |
Scan Tool Output Control | Additional Menu Selection(s) | Description |
---|---|---|
A/C Relay | -- | The scan tool displays On or Off selections. This command allows you to turn the A/C relay ON or OFF. |