The numbers below refer to the step numbers on the diagnostic table.
The DTCs listed may set, if there is a concern with the actuator, when a calibration of the actuators is performed.
Ambient air temperature must be above 3°C (38°F) in order for this A/C compressor test to be run.
Misaligned air baffles will cause poor A/C performance at idle and low speed operation.
The specified values are from the A/C System Performance Test.
This action ensures that the internal fan of the inside air temperature sensor assembly is providing air flow across the internal sensor.
Step | Action | Values | Yes | No |
---|---|---|---|---|
Schematic Reference: HVAC Schematics DEFINITION: Temperature can not be adjusted, or cooling insufficient during A/C operation. | ||||
1 | Did you perform the HVAC Diagnostic System Check? | -- | Go to Step 2 | |
Important: If during this diagnostic procedure the HVAC control module is disconnected a recalibration of actuators must be performed to avoid misdiagnosis.
Does the scan tool display any DTC B0229, B0414, B0434 or B3761? | -- | Go to Step 3 | ||
Important:: Ambient air temperature must be above 3°C (38°F).
Does the A/C compressor operate? | -- | Go to Step 4 | ||
Inspect the air baffles for proper installation. Refer to Radiator Air Baffle Assemblies and Deflectors in Engine Cooling. Did you find and correct the condition? | -- | Go to Step 25 | Go to Step 5 | |
5 | Does the blower operate and provide sufficient air flow? | -- | Go to Step 6 | Go to Blower Motor Malfunction |
Perform the refrigerant system performance test. Refer to Air Conditioning (A/C) System Performance Test . Did the system pass the A/C System Performance Test? | -- | Go to Step 7 | Go to Air Conditioning (A/C) System Performance Test in Heating, Ventilation and Air Conditioning | |
7 | Check the air temperature sensors for proper installation. Refer to the following procedures: Did you find and correct the condition? | -- | Go to Step 25 | Go to Step 8 |
Does the paper stay in place? | -- | Go to Step 9 | Go to Step 13 | |
9 |
Does the scan tool indicate that the solar sensor parameter is greater than the specified value? | 230 Counts | Go to Step 10 | Go to Step 19 |
10 |
Do the counts change? | -- | Go to Step 11 | Go to Step 19 |
11 |
Does the scan tool indicate sensor temperature is within 3°C (5°F) of the thermometer temperature? | -- | Go to Step 12 | Go to Step 16 |
12 |
Does the resistance measure near the sensor resistance table value? | -- | System OK | Go to Step 18 |
13 | Inspect for a blocked or malfunctioning inside air temperature sensor. Did you find and correct the condition? | -- | Go to Step 25 | Go to Step 14 |
14 | Test the ignition 1 voltage circuit of the inside air temperature sensor for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 25 | Go to Step 15 |
15 | Test the ground circuit of the inside air temperature sensor for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 25 | Go to Step 17 |
16 |
Does the resistance measure near the specified value? | -- | Go to Step 20 | Go to Step 17 |
17 | Inspect for poor connections at the harness connector of the inside air temperature sensor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 25 | Go to Step 23 |
18 | Inspect for poor connections at the harness connector of the upper and lower air temperature sensors. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 25 | Go to Step 21 |
19 | Inspect for poor connections at the harness connector of the sunload sensor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 25 | Go to Step 22 |
20 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 25 | Go to Step 24 |
21 | Replace the suspect air temperature sensor. Refer to one of the following procedures: Did you complete the replacement? | -- | Go to Step 25 | -- |
22 | Replace the sunload sensor. Refer to Sun Load Sensor Replacement . Did you complete the replacement? | -- | Go to Step 25 | -- |
23 | Replace the inside air temperature sensor. Refer to Inside Air Temperature Sensor Replacement . Did you complete the replacement? | -- | Go to Step 25 | -- |
24 |
Important:: Perform the recalibration procedure for the HVAC control module. Replace the HVAC control module. Refer to HVAC Control Module Replacement . Did you complete the replacement? | -- | Go to Step 25 | -- |
25 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |