Scan Tool Output Control | Additional Menu Selection(s) | Description | ||||
---|---|---|---|---|---|---|
EGR Solenoid | Engine Output Controls | Activates the exhaust gas recirculation (EGR) solenoid that controls EGR valve position. The normal commanded state is NONE. The system will INCREASE or DECREASE the amount of EGR opening by 10 percent increments within a range of 0-100 percent. The system remains in the commanded state until cancelled by the tool. If the engine is running, too much EGR will result in a rough idle and/or stalling. | ||||
EVAP Purge | Engine Output Controls/EVAP System | Activates the evaporative emission (EVAP) purge valve. The normal commanded state is NONE. The system will INCREASE or DECREASE the amount of EVAP purge valve opening by 10 percent increments within a range of 0-100 percent. The system remains in the commanded state until cancelled by the tool or the fuel tank pressure exceeds 24 mmHg (12 in H20). | ||||
EVAP Purge/Seal | Engine Output Controls / EVAP System | This control enables two functions. One function increases or decreases the amount of purge by changing the duty cycle of the purge valve and commanding the vent ON, non-venting. The normal commanded state of both valves is NONE. The system will INCREASE or DECREASE the amount of EVAP purge valve opening by 10 percent increments within a range of 0-100 percent. The second function seals the system after using the purge function to obtain a specific amount of fuel tank pressure. When activated the purge valve is commanded to 0 percent and the vent valve is commanded ON, non-venting. Both functions remain in the commanded state until cancelled by the tool or the fuel tank pressure exceeds 24 mmHg (12 in H20). | ||||
EVAP Vent | Engine Output Controls / EVAP System | Activates the EVAP vent solenoid. The normal commanded state is NONE. When commanded ON, the vent valve switches to non-venting. The system remains in the commanded state unless one of the following conditions occurs:
| ||||
Fuel Pump | Engine Output Controls | Controls the fuel pump relay. The normal commanded state is NONE. When commanded ON/OFF, the powertrain control module (PCM) turns the fuel pump ON/OFF. If the engine is running, and the fuel pump is commanded OFF, the engine will stall. The system remains in the commanded state until cancelled by the scan tool. | ||||
Loop Status | Engine Output Controls | Controls the system loop status. The commanded states include NONE, OPEN, or CLOSED. The normal commanded state is NONE. When commanded OPEN or CLOSED, the system remains in the commanded state until cancelled by the scan tool. | ||||
Malfunction Indicator Lamp | Engine Output Controls | Controls the malfunction indicator lamp (MIL). The commanded states include NONE, ON, and OFF. When commanded ON or OFF, the system remains in the commanded state until cancelled by the scan tool. | ||||
O2S Heater Driver 1 | Engine Output Controls | Activates the following heated oxygen sensor (HO2S) heaters:
The commanded states include NONE, ON, and OFF. The normal commanded state is NONE. Commanding O2S heater driver 1 ON turns ON both heater driver 1 and heater driver 3. On a cold engine, with the key ON, engine OFF, the HO2S signals will continue to drop below bias when commanded ON. The system remains in the commanded state until cancelled by the tool. | ||||
O2S Heater Driver 3 | Engine Output Controls | Activates the HO2S bank 2 sensor 1 heater. The commanded states include NONE, ON, and OFF. The normal commanded state is NONE. Commanding O2S heater driver 3 ON turns ON heater driver 3 only. On a cold engine, with the key ON, engine OFF, the HO2S signal will continue to drop below bias when commanded ON. The system remains in the commanded state until cancelled by the tool. | ||||
O2S Heater Driver 4 | Engine Output Controls | Activates the HO2S bank 1 sensor 2 heater. The commanded states include NONE, ON, and OFF. The normal commanded state is NONE. Commanding O2S heater driver 4 ON turns ON heater driver 4 only. On a cold engine, with the key ON, engine OFF, the HO2S signal will continue to drop below bias when commanded ON. The system remains in the commanded state until cancelled by the tool. |