Table 1: | A/C Performance Table |
This test measures the operating efficiency of the A/C system under the following conditions:
• | The current ambient air temperature |
• | The current relative humidity |
• | The high side pressure of the A/C system |
• | The low side pressure of the A/C system |
• | The temperature of the air being discharged into the passenger compartment |
The numbers below refer to the step numbers on the diagnostic table.
This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.
This step measures the performance of the A/C system.
This step is to allow for vehicle variations as well as high ambient air temperatures.
Step | Action | Values | Yes | No | ||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Important:
| ||||||||||||||||||||||||||||||
Are both the low and high side pressures within the specified value? |
| Go to Step 2 | Go to Leak Testing | |||||||||||||||||||||||||||
Important: Record the relative humidity and the ambient air temperature at the time of the test.
Important: Press the RESET button, before using the print function of theJ 43600 .
Does all the data recorded fall within the specified ranges of the table below? | -- | Go to Step 8 | Go to Step 3 | |||||||||||||||||||||||||||
If the pressures and temperatures recorded do not fall within the specified ranges:
Does all the data recorded fall within the specified ranges of the table below? | -- | Go to Step 8 | Go to Step 4 | |||||||||||||||||||||||||||
4 | Do the high and low side pressures fall within the specified ranges but the panel outlet temperatures do not? | -- | Go to Step 5 | |||||||||||||||||||||||||||
5 | Is the low side pressure greater than the specified range, but the high side pressure within or less than the specified range? | -- | Go to Step 6 | |||||||||||||||||||||||||||
6 | Are the low and high side pressures both greater than the specified ranges? | -- | Go to Step 7 | |||||||||||||||||||||||||||
7 | Is the high side pressure greater than the specified range, but the low side pressure is within or less than the specified range? | -- | Go to Step 8 | |||||||||||||||||||||||||||
8 | Operate the system in order to verify the test results. Did you find the same results? | -- | System OK | Go to Symptoms - HVAC Systems - Manual in HVAC Systems - Manual or Symptoms - HVAC Systems - Automatic in HVAC Systems - Automatic |
Ambient Air Temperature | Relative Humidity | Service Port Pressure | Maximum Left Center Discharge Air Temperature | |
---|---|---|---|---|
Low Side | High Side | |||
13-16°C (55-65°F) | 0-100% | 175-206 kPa (25-30 psi) | 340-850 kPa (49-123 psi) | 7°C (45°F) |
19-24°C (66-75°F) | Below 40% | 175-215 kPa (25-31 psi) | 430-930 kPa (62-135 psi) | 6°C (43°F) |
Above 40% | 175-254 kPa (25-37 psi) | 570-1070 kPa (83-155 psi) | 9°C (48°F) | |
25-29°C (76-85°F) | Below 35% | 175-249 kPa (25-36 psi) | 760-1410 kPa (147-205 psi) | 9°C (42°F) |
35-60% | 175-261 kPa (26-38 psi) | 830-1180 kPa (120-171 psi) | 10°C (50°F) | |
Above 60% | 185-286 kPa (27-42 psi) | 880-1250 kPa (128-181 psi) | 11°C (52°F) | |
30-35°C (86-95°F) | Below 30% | 193-293 kPa (28-43 psi) | 1010-1410 kPa (146-205 psi) | 12°C (54°F) |
30-50% | 228-269 kPa (30-44 psi) | 1050-1440 kPa (153-209 psi) | 13°C (55°F) | |
Above 50% | 221-324 kPa (32-47 psi) | 1100-1470 kPa (160-213 psi) | 14°C (58°F) | |
36-41°C (96-105°F) | Below 20% | 241-337 kPa (35-47 psi) | 1310-1700 kPa (190-246 psi) | 16°C (61°F) |
20-40% | 247-345 kPa (36-50 psi) | 1320-1700 kPa (190-230 psi) | 16°C (61°F) | |
Above 40% | 259-353 kPa (37-52 psi) | 1350-1690 kPa (196-246 psi) | 16°C (61°F) | |
42-46°C (106-115°F) | Below 20% | 292-378 kPa (42-55 psi) | 1630-1950 kPa (238-283 psi) | 17°C (62°F) |
Above 20% | 297-383 kPa (43-55 psi) | 1620-1930 kPa (235-280 psi) | 19°C (66°F) | |
47-49°C (116-120°F) | Below 30% | 338-405 kPa (50-59 psi) | 187-2080 kPa (271-302 psi) | 20°C (68°F) |