Removal Procedure
- Remove the instrument cluster trim plate bezel. Refer to
Instrument Panel Cluster Trim Plate Bezel Replacement
in Instrument Panel,
Gages, and Console.
- Remove the instrument panel storage tray.
- Remove the accessory switch assembly from the instrument panel.
Refer to
Accessory Switch Replacement
in Instrument Panel, Gages, and Console.
- Remove the screws from the HVAC control assembly.
- Remove the HVAC control
assembly, with the following procedure:
5.1. | Release the retaining tabs. |
5.2. | Pull the control head out of the instrument panel carrier. |
- Disconnect the electrical connectors from the HVAC control assembly.
Installation Procedure
- Connect the electrical
connectors to the HVAC control assembly.
- Install the HVAC control assembly.
- Install the accessory switch assembly to the instrument panel.
Refer to
Accessory Switch Replacement
in Instrument Panel, Gages, and Console.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the screws from
the HVAC control assembly.
Tighten
Tighten the screws to 1.9 N·m (17 lb in).
- Install the instrument panel storage tray.
- Install the instrument cluster trim plate bezel. Refer to
Instrument Panel Cluster Trim Plate Bezel Replacement
in Instrument Panel,
Gages, and Console.