Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Interior Lights Schematics | |||
1 | Did you perform the Lighting Diagnostic System Check? | Go to Step 2 | |
2 | Operate the cargo lamps to verify the fault is present. Does the system operate normally? | Go to Testing for Electrical Intermittents in Wiring Systems | Go to Step 3 |
3 |
Does the cargo lamp function properly? | Go to Step 4 | Go to the appropriate diagnostic chart: Cargo Lamp Always On or Cargo Lamp Inoperative |
4 |
Does the message turn on and off when commanded? | Go to Step 7 | Go to Step 5 |
5 | Inspect for poor connections at the harness connector of the instrument panel cluster (IPC). Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 7 | Go to Step 6 |
6 | Replace the IPC. Refer to Instrument Cluster Replacement in Instrument Panel, Gages, and Console. Did you complete the replacement? | Go to Step 7 | -- |
7 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |