Removal Procedure
- Reposition the generator control module (GCM) coolant tank hose clamp (2) from the GCM coolant tank (3).
- Remove the GCM coolant tank hose (1) from the GCM coolant tank (3).
- Reposition the GCM coolant tank hose clamp (4) from the GCM (5).
- Remove the GCM coolant tank hose (1) from the GCM (5).
Installation Procedure
- Install the GCM coolant tank hose (1) to the GCM (5).
- Position the GCM coolant tank hose clamp (4) to the GCM (5).
- Install the GCM coolant tank hose (1) to the GCM coolant tank (3).
- Position the GCM coolant tank hose clamp (2) to the GCM coolant tank (3).
Notice: The procedure below must be followed. Improper coolant level could result in
a low or high coolant level condition, causing starter/generator control module damage.
- Top off the GCM cooling system. Refer to
Generator Control Module Cooling System Draining and Filling
.