GM Service Manual Online
For 1990-2009 cars only

Air Inlet Valve Actuator Replacement Delphi

Removal Procedure

Notice: In order to avoid actuator damage, DO NOT apply power to the actuator when it is not installed in the HVAC module.

  1. Remove the air distribution duct. Refer to Air Distributor Duct Replacement .

  2. Object Number: 372310  Size: SH
  3. Disconnect the electrical connection from the recirculation actuator (1).

  4. Object Number: 363786  Size: SH
  5. Remove the recirculation actuator retaining screws.
  6. Remove the recirculation actuator.

Installation Procedure


    Object Number: 363786  Size: SH
  1. Install the recirculation actuator.
  2. Notice: Refer to Fastener Notice in the Preface section.

  3. Install the recirculation actuator retaining screws.
  4. Tighten
    Tighten the screws to 1.6 N·m (14 lb in).


    Object Number: 372310  Size: SH
  5. Connect the electrical connector to the recirculation actuator (1).
  6. Install the air distribution duct. Refer to Air Distributor Duct Replacement .

Air Inlet Valve Actuator Replacement Visteon

Removal Procedure

  1. Remove the HVAC module assembly. Refer to HVAC Module Assembly Replacement .

  2. Object Number: 826695  Size: SH
  3. Remove the screws from the evaporator core cover (1).
  4. Remove the evaporator core cover (1) from the HVAC module assembly (2).

  5. Object Number: 826725  Size: SH
  6. Remove the screws from the recirculation actuator (1).
  7. Remove the recirculation actuator (1) from the HVAC module assembly (2).

Installation Procedure


    Object Number: 826725  Size: SH
  1. Install the recirculation actuator (1) to the HVAC module assembly (2).
  2. Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.

  3. Install the screws to the recirculation actuator (1).
  4. Tighten
    Tighten the screws to 2 N·m (18 lb in).

  5. Install the evaporator core cover (1) to the HVAC module assembly (2).

  6. Object Number: 826695  Size: SH
  7. Install the screws to the evaporator core cover (1).
  8. Tighten
    Tighten the screws to 2 N·m (18 lb in).

  9. Install the HVAC module assembly. Refer to HVAC Module Assembly Replacement .
  10. Reprogram the recirculation actuator. Refer to Actuator Recalibration .