Air Inlet Valve Actuator Replacement Delphi
Removal Procedure
Notice: In order to avoid actuator damage, DO NOT apply power to the actuator when it is not installed in the HVAC module.
- Remove the air distribution duct. Refer to
Air Distributor Duct Replacement
.
- Disconnect the electrical connection from the recirculation actuator (1).
- Remove the recirculation actuator retaining screws.
- Remove the recirculation actuator.
Installation Procedure
- Install the recirculation actuator.
Notice: Refer to Fastener Notice in the Preface section.
- Install the recirculation actuator retaining screws.
Tighten
Tighten the screws to 1.6 N·m (14 lb in).
- Connect the electrical connector to the recirculation actuator (1).
- Install the air distribution duct. Refer to
Air Distributor Duct Replacement
.
Air Inlet Valve Actuator Replacement Visteon
Removal Procedure
- Remove the HVAC module assembly. Refer to
HVAC Module Assembly Replacement
.
- Remove the screws from the evaporator core cover (1).
- Remove the evaporator core cover (1) from the HVAC module assembly (2).
- Remove the screws from the recirculation actuator (1).
- Remove the recirculation actuator (1) from the HVAC module assembly (2).
Installation Procedure
- Install the recirculation actuator (1) to the HVAC module assembly (2).
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the screws to the recirculation actuator (1).
Tighten
Tighten the screws to 2 N·m (18 lb in).
- Install the evaporator core cover (1) to the HVAC module assembly (2).
- Install the screws to the evaporator core cover (1).
Tighten
Tighten the screws to 2 N·m (18 lb in).
- Install the HVAC module assembly. Refer to
HVAC Module Assembly Replacement
.
- Reprogram the recirculation actuator. Refer to
Actuator Recalibration
.