Removal Procedure
- Remove the oil level indicator.
- Remove the oil level indicator tube bolt.
- Remove the oil level indicator tube from the engine block.
Important: The O-ring seal may be reused if not cut or damaged.
- Inspect the O-ring seal for cuts or damage.
- Remove the O-ring seal from the tube, if required.
Installation Procedure
- Lubricate the O-ring seal with clean engine oil.
- Install a NEW O-ring seal onto the oil level indicator tube, if required.
- Install the oil level indicator tube between the exhaust manifold and engine block.
- Raise and suitably support the vehicle. Refer to
Lifting and Jacking the Vehicle
.
- Install the oil level indicator tube into the block. The tube must be installed with the collar flush to the block.
- Lower the vehicle.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the oil level indicator tube bolt.
Tighten
Tighten the bolt to 25 N·m (18 lb ft).
- Install the oil level indicator.